首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Liquid chromatographic determination of amodiaquine in human plasma
【24h】

Liquid chromatographic determination of amodiaquine in human plasma

机译:液相色谱法测定人血浆中的氨二喹

获取原文
获取原文并翻译 | 示例
           

摘要

A normal-phase high-performance liquid chromatographic method using dichloromethane– methanol–1 M perchloric acid (100:10:0.9, v/v/v) at a flow rate of 1.0 ml min~(-1) on a LiChrospher Si column with UV (254 nm) detection has been developed for the determination of amodiaquine and its metabolites desethyl amodiaquine and bisdesethyl amodiaquine in plasma. The limit of quantification was 5 ng ml~(-1). Mean within-day and day-to-day coefficients of variation (CV) were 4.10 and 6.27% for amodiaquine, 3.43 and 4.80% for desethyl amodiaquine and 3.53 and 5.23% for bisdesethyl amodiaquine, respectively. Mean extraction recovery of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine from plasma were 82.48, 74.50 and 69.65%, respectively. Chloroquine and its metabolite desethyl chloroquine, quinine, sulfadoxine and primaquine do not interfere in the detection of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine in plasma.
机译:使用二氯甲烷-甲醇-1 M高氯酸(100:10:0.9,v / v / v)于LiChrospher Si柱上以1.0 ml min〜(-1)的流速进行正相高效液相色谱法紫外(254 nm)检测器已经开发出来,可用于测定血浆中的氨二喹及其代谢物脱乙基氨二喹和双乙基氨二喹。定量限为5 ng ml〜(-1)。日间和日间平均变异系数(CV)对氨二喹而言是分别为4.10和6.27%,对去乙基氨二喹而言为3.43和4.80%,对于对二乙基氨二喹而言为3.53和5.23%。从血浆中提取的氨二喹,去乙基氨二喹和双去乙基氨二喹的平均回收率分别为82.48、74.50和69.65%。氯喹及其代谢产物去乙基氯喹,奎宁,磺胺多辛和伯氨喹不会干扰血浆中氨二喹,去乙基氨二喹和双去乙基氨二喹的检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号