首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Determination of monoamines in urine by capillary electrophoresis with field-amplified sample stacking and amperometric detection
【24h】

Determination of monoamines in urine by capillary electrophoresis with field-amplified sample stacking and amperometric detection

机译:毛细管电泳-场放大样品叠加-安培检测法测定尿中单胺

获取原文
获取原文并翻译 | 示例
           

摘要

A simple, rapid and low-cost method using capillary electrophoresis coupled with field-amplified sample stacking and electrochemical detection was developed for the separation and determination of monoamines. In this present work, a systematic study of the parameters (pH value and concentration of electrophoretic buffer, composition of sample solvent, injection voltage and time) affecting separation and on-line concentration of monoamines has been performed enabling the detection sensitivity of these monoamines to be improved by 5000 times compared with the conventional electrokinetic injection. This developed method was applied to the direct analysis of these monoamines in human urine without off-line sample preconcentration. Due to the requirement for urine dilution to minimize the detrimental effects of high salt on analyte stacking, the real sensitivity improvement is about 50-fold when applying the optimized method to urine samples. In order to quantitate these monoamines accurately, internal standard calibration curves were constructed with standard monoamines in presence of salt with similar concentration as in human urine. In the method validation, the calibration curves were linear over a range of 1.0 x 10(-9) to 2.5 x 10(-8) mol/L for each monoamine and the limits of detection (signal to noise ratio of 3) for these monoamines were in the sub-nmol/L concentration range (6.0 x 10(-10) mol/L). (c) 2006 Elsevier B.V. All rights reserved.
机译:开发了一种简单,快速,低成本的毛细管电泳与现场扩增样品堆叠和电化学检测相结合的方法,用于分离和测定单胺。在本工作中,对影响单胺的分离和在线浓度的参数(pH值和电泳缓冲液浓度,样品溶剂的组成,进样电压和时间)进行了系统的研究,从而使这些单胺的检测灵敏度达到与传统的电动注射相比,可提高5000倍。这种发达的方法可用于直接分析人尿中的这些单胺,而无需离线进行样品预浓缩。由于需要尿液稀释以最大程度地减少高盐对分析物堆积的不利影响,因此,将优化方法应用于尿液样品时,实际灵敏度提高了约50倍。为了准确定量这些单胺,在盐浓度与人尿中相似的情况下,用标准单胺构建了内标校正曲线。在方法验证中,每种单胺的校准曲线在1.0 x 10(-9)mol / L到2.5 x 10(-8)mol / L的范围内是线性的,并且这些化合物的检出限(信噪比为3)单胺的浓度低于nmol / L(6.0 x 10(-10)mol / L)。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号