The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 μl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 μm I.D. * 30 mm 10 μm Kromasil C_(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 μm I.D. * 100 mm 3.5 μm Kromasil C_(18) analytical column. Loading flow rates up to 100 μl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H]~- at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.
机译:本工作报告了毛细管液相色谱柱切换方法,该方法适用于使用微电喷雾电离飞行时间质谱检测技术快速,灵敏和选择性地测定人尿中的1-羟基py(1-OHP)。将解偶联,水稀释和过滤后的尿液样品(100μl)加载到150μmI.D. * 30毫米10μmKromasil C_(18)预柱,提供在线样品清洁和分析物富集,然后反冲洗到150μmI.D. * 100 mm 3.5μmKromasil C_(18)分析柱通过使用含有5 mM醋酸铵的乙腈/水(70/30,v / v)的流动相组合物进行等度洗脱,负载流速高达100μl/ min,可在5.5分钟内洗脱1-OHP手动操作的总分析时间少于15分钟。在负离子模式下进行电离,在m / z 217.08处观察到1-OHP为[M-H]〜-。该方法在预处理尿液中的0.2-40 ng / ml 1-OHP浓度范围内得到验证,相关系数为0.997。测定内(n = 6)和测定间(n = 6)的精密度分别在6.4-7.3和7.0-8.1%范围内,并且在所研究的浓度范围内,回收率在96.2-97.5范围内。方法的检测质量极限为2 pg,对应于20 pg / ml(0.09 nmol / l)稀释尿液或0.3 ng / ml(1.35 nmol / l)尿液的1-OHP浓度极限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号