Depletion and replenishment characteristics of molecularly thin perfluoropolyether (PFPE) lubricant film were studied using a pin-on-disk sliding test using a glass ball and magnetic disks coated with hydrogenated diamondlike carbon. Depletion and accumulation of the lubricant film after sliding tests performed with or without seek motion and recovery processes toward original flat surface were measured using an optical surface analyzer (OSA). An anomalous phenomenon of polar lubricant unrecoverable against lubricant depletion was observed first. This phenomenon occurs when the residual film thickness after depletion nearly equals a monolayer of a polar PFPE molecule independent of initial film thickness. In addition, recovery rates, defined as the ratio of depletion area or accumulation area to their initial values, were quantified for polar and nonpolar lubricants. The recovery rates are found to have a nearly linear relationship with varying elapsed time expressed in a logarithmic scale.
机译:使用玻璃球和涂有氢化钻石状碳的磁盘对磁盘进行销钉滑动试验,研究了分子薄的全氟聚醚(PFPE)润滑剂薄膜的损耗和补给特性。使用光学表面分析仪(OSA)测量在进行或不进行寻道运动和向原始平坦表面的恢复过程的滑动测试后,润滑膜的损耗和堆积。首先观察到极性润滑剂的异常现象,该现象是针对润滑剂耗竭无法恢复的。当耗尽后的剩余膜厚度几乎等于极性PFPE分子的单层,而与初始膜厚度无关时,会发生此现象。此外,对极性和非极性润滑剂的回收率(定义为消耗面积或累积面积与初始值的比)进行了定量。发现回收率与以对数刻度表示的变化的经过时间具有几乎线性的关系。