首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >DETERMINATION OF ANTIMONY IN URINE, BLOOD AND SERUM AND IN LIVER AND LUNG TISSUES OF INFANTS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
【24h】

DETERMINATION OF ANTIMONY IN URINE, BLOOD AND SERUM AND IN LIVER AND LUNG TISSUES OF INFANTS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

机译:电感耦合等离子体质谱法测定婴儿尿液,血液,血清及肝,肺组织中的锑

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Methods are presented for the determination by ICP-MS of antimony in body fluids and tissues of infants, Urine, serum and whole blood specimens are prepared for analysis by simply diluting 200 mu l sample volumes (1 + 14) with water and adding indium as internal standard, fiver and lung tissues are digested using 16 M HNO3 either in open quartz vessels at 150 degrees C or in sealed vessels with microwave heating, The acid digests are diluted with water and indium is added as internal standard for ICP-MS measurements, All analyses were subjected to stringent internal quality control protocols, Accuracy was assessed by recoveries, repeated analyses and by analysis of NIST SRMs 1577a Bovine Liver and 1566a Oyster Tissue, Precisions of analyses were better than 5-10% in the ranges 0.1-0.3 mu g l(-1) for urine, serum and blood; acid at 7-25 ng g(-1) in tissues. Detection limits were 0.7 ng g(-1) in liver, 0.8 ng g(-1) in lung, and 0.01 mu g l(-1) in urine, serum and blood, The need to employ validated procedures for specimen collection and to give considerable attention to pre-analytical factors in order to avoid adventitious contamination with antimony is demonstrated. [References: 12]
机译:提出了ICP-MS测定婴儿体液和组织中锑的方法,只需用水稀释200μl样品体积(1 + 14)并加入铟作为样品,即可制备尿液,血清和全血样品以进行分析。使用16 M HNO3在150°C的开放式石英容器中或在微波加热的密封容器中消解内脏,肝脏和肺组织。酸消解物用水稀释,并添加铟作为ICP-MS测量的内标,所有分析均经过严格的内部质量控制规程,通过回收率,重复分析和NIST SRM 1577a牛肝和1566a牡蛎组织的分析来评估准确性,分析精度在0.1-0.3微米范围内优于5-10% gl(-1)用于尿液,血清和血液;在组织中的酸浓度为7-25 ng g(-1)。检出限为:肝中0.7 ng g(-1),肺中0.8 ng g(-1),尿液,血清和血液中0.01μgl(-1)。需要采用经过验证的程序进行标本采集并提供展示了对分析前因素的极大关注,以避免锑偶然污染。 [参考:12]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号