首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >A common method for the determination of several calcium channel blockers using an HPLC system with ultraviolet detection
【24h】

A common method for the determination of several calcium channel blockers using an HPLC system with ultraviolet detection

机译:使用紫外检测HPLC系统测定几种钙通道阻滞剂的常用方法

获取原文
获取原文并翻译 | 示例
           

摘要

We report a common HPLC method for the single or simultaneous determination of four calcium channel blockers (CCB), namely diltiazem (DTZ), verapamil (VER), nifedipine (NIF) and nitrendipine (NIT) and their active metabolites demetildiltiazem and deacetildiltiazem (MA and M1), norverapamil (NOR), and dehydronifedipine (DHN). DHN was first synthesised in our laboratory and different pH values of the mobile phase were subsequently prepared and tested for chromatographic separation. The detection system and the environmental light conditions were optimised. The best separations of all analytes were obtained using a C_(18) column and a mobile phase of methanol, 0.04 M ammonium acetate, acetonitrile and triethylamine (2:2:1:0.04 v/v). Quantitation was performed using imipramine (IMI) as the internal standard. For DTZ and its metabolites (M1 and MA), the wavelength chosen was 237 nm; for VER and its metabolite NOR, it was 210 nm; and, finally for NIF and its metabolite DHN and NIT it was 216 nm.When a simultaneous analysis was carried out the wavelength was of 230 nm. The optimum pH were 7.90 and 7.10 when the separation of NIT and DTZ or VER and NIF were carried out, respectively, and 7.90 when a simultaneous separation was carried out. The detection limit of the assay was less than 8 ng ml~(-1) for all compounds, with coefficients of variation less than 7% (for inter- and intra-day) over the concentration range of 1-1000 ng ml~(-1). The retention times were less than 11 min. When NIF or NiT were studied, it was necessary to use a sodium vapour lamp in order to avoid the photodegradation which takes place under daylight conditions.
机译:我们报告了一种用于单个或同时测定四种钙通道阻滞剂(CCB)的常用HPLC方法,即地尔硫卓(DTZ),维拉帕米(VER),硝苯地平(NIF)和硝苯地平(NIT)及其活性代谢物脱甲地尔地西ze和脱乙腈和M1),去甲维拉帕米(NOR)和脱氢硝苯地平(DHN)。 DHN首先在我们的实验室中合成,随后制备了不同pH的流动相,并进行了色谱分离测试。检测系统和环境光条件进行了优化。使用C_(18)色谱柱和甲醇,0.04 M乙酸铵,乙腈和三乙胺(2:2:1:0.04 v / v)的流动相可实现所有分析物的最佳分离。使用丙咪嗪(IMI)作为内标进行定量。对于DTZ及其代谢物(M1和MA),选择的波长为237 nm。 VER及其代谢产物NOR为210 nm;最后,对于NIF及其代谢产物DHN和NIT,其波长为216 nm。同时进行分析时,波长为230 nm。当进行NIT和DTZ分离或VER和NIF分离时,最佳pH分别为7.90和7.10,同时进行分离时的最佳pH为7.90。所有化合物的测定检出限均小于8 ng ml〜(-1),在1-1000 ng ml〜(浓度范围内)的变异系数小于7%(日间和日内)。 -1)。保留时间少于11分钟。在研究NIF或NiT时,必须使用钠蒸气灯,以避免在日光条件下发生光降解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号