OBJECTIVE: Development of a rat model of persistent peritonitis and evaluation of the ability of liposomal ciprofloxacin hydrogel-coated silicone to resist colonization. DESIGN: A newly developed model of persistent Pseudomonas aeruginosa peritonitis to compare the ability of liposomal ciprofloxacin hydrogel (LCH)-coated silicone versus plain silicone for resistance to bacterial colonization. ANIMALS: Male Sprague-Dawley rats. RESULTS: Inoculating the peritoneum of rats with 1 mL 0.5% agar containing 10(6) colony-forming units (cfu)/mL P. aeruginosa in the presence of a plain silicone coupon resulted in persistent peritonitis for at least 7 days. Plain silicone coupons in all 40 rats were colonized (median 2.54 x 10(3) cfu/cm2; range 5.0 x 10(1)-1.0 x 10(6) cfu/cm2) and peritoneal washings were consistently culture-positive. In contrast, the LCH coupons removed after 7 days from the 40 test rats were sterile, as were the peritoneal washings, and there was no evidence of peritonitis. Blood cultures were negative in both groups. CONCLUSIONS: Liposomal ciprofloxacin hydrogel-coated silicone resists colonization in this rat model of persistent P. aeruginosa peritonitis.
机译:目的:建立持续性腹膜炎大鼠模型并评价脂质体环丙沙星水凝胶包覆的有机硅抵抗定植的能力。设计:一种新开发的持续性铜绿假单胞菌腹膜炎模型,用于比较脂质体环丙沙星水凝胶(LCH)涂层有机硅与普通有机硅对细菌定殖的抵抗力。动物:雄性Sprague-Dawley大鼠。结果:在普通硅酮试样存在下,向大鼠腹膜接种含10(6)/菌落形成单位(cfu)/ mL铜绿假单胞菌的1 mL 0.5%琼脂,导致持续性腹膜炎至少7天。将所有40只大鼠的纯硅树脂试样定殖(中值2.54 x 10(3)cfu / cm2;范围5.0 x 10(1)-1.0 x 10(6)cfu / cm2),腹膜冲洗液始终培养阳性。相比之下,从40只试验大鼠中取出的LCH息肉在7天后是无菌的,腹膜冲洗液也是无菌的,没有腹膜炎的迹象。两组的血培养均为阴性。结论:在持续性铜绿假单胞菌腹膜炎大鼠模型中,脂质体环丙沙星水凝胶包覆的硅酮可抵抗定植。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号