首页> 外文期刊>Ultrasound in obstetrics & gynecology: the official journal of the International Society of Ultrasound in Obstetrics and Gynecology >Fetal Intelligent Navigation Echocardiography (FINE): A novel method for rapid, simple, and automatic examination of the fetal heart
【24h】

Fetal Intelligent Navigation Echocardiography (FINE): A novel method for rapid, simple, and automatic examination of the fetal heart

机译:胎儿智能导航超声心动图(FINE):一种快速,简单和自动检查胎儿心脏的新方法

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. Methods: We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance?)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance? were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). Results: In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance? in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance? in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. Conclusions The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify examination of the fetal heart and reduce operator dependency. The observation of abnormal echocardiography views in the diagnostic planes and/or VIS-Assistance? should raise the index of suspicion for congenital heart disease.
机译:目的:描述一种新的方法(胎儿智能导航超声心动图(FINE)),该方法可从时空图像相关性(STIC)获得的体数据集中可视化标准胎儿超声心动图视图,并应用“智能导航”技术。方法:我们开发了一种方法:1)演示九个心脏诊断平面; 2)自发地导航围绕9个心脏诊断平面中的每一个的解剖结构(虚拟智能超声检查仪协助(VIS-Assistance?))。该方法包括标记胎儿心脏的七个解剖结构。然后自动生成以下超声心动图视图:1)四个腔室; 2)五室; 3)左心室流出道; 4)大血管/右心室流出道的短轴视图; 5)三个血管和气管; 6)腹部/胃; 7)导管弓; 8)主动脉弓; 9)上腔静脉和下腔静脉。 FINE方法在另一组50例STIC正常心脏(妊娠期18.6-37.2周)中进行了测试,并使用诊断平面和/或VIS-Assistance对胎儿超声心动图视图的可视化率进行了测试。被计算。为了检验识别异常心脏解剖结构的可行性,我们在四例先天性心脏缺陷(主动脉缩窄,法洛四联症,大血管移位和完整室间隔的肺动脉闭锁)中对这种方法进行了测试。结果:在正常情况下,FINE方法能够使用以下方法生成九个胎儿超声心动图视图:1)在78-100%的病例中使用诊断平面; 2)VIS-Assistance?在98-100%的情况下;和3)诊断平面和/或VIS-Assistance的组合?在98-100%的情况下。在所有四个异常情况下,FINE方法均显示出胎儿心脏解剖结构异常的证据。结论通过将“智能导航”技术应用于STIC体积数据集,FINE方法可用于可视化正常心脏中的九种标准胎儿超声心动图视图。该方法可以简化胎儿心脏的检查并减少操作者的依赖性。在诊断平面和/或VIS-Assistance中是否观察到异常的超声心动图视图?应提高对先天性心脏病的怀疑指数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号