Numerical simulation is increasingly being used to predict the flowfield within patient-specific geometries of abdominal aortic aneurysms under physiologically realistic flow conditions. This paper reports on a comparison between the flowfield measured in vitro within a patient-specific model of a mature abdominal aortic aneurysm and that predicted using computational fluid dynamics (CFD). Visualization and traverses of axial velocity were obtained at a number of locations in the aneurysm region under both steady and physiologically realistic pulsatile flow conditions. Comparisons between the measured and predicted flowfield show good agreement throughout the aneurysm. Although turbulence was observed distal in the aneurysm during late diastole, best agreement was achieved using a simple laminar flow model.
机译:在生理现实的流动条件下,数值模拟越来越多地用于预测腹主动脉瘤患者特定几何形状内的流场。本文报告了在成熟的腹主动脉瘤患者特定模型中体外测量的流场与使用计算流体力学(CFD)预测的流场之间的比较。在稳定和生理上真实的脉动血流条件下,在动脉瘤区域的许多位置获得了轴向速度的可视化和遍历。在整个动脉瘤中,实测流场和预测流场之间的比较显示出良好的一致性。尽管在舒张末期在动脉瘤远端观察到湍流,但使用简单的层流模型可达到最佳一致性。