Any pharmaceutical facility that handles biological agents (e.g., pathogens or genetically modified organisms) must employ appropriate biocontainment precautions. Laboratory and manufacturing areas are assigned a designation of Biosafety Level 1 through Biosafety Level 4 (BSL-1 through BSL-4), reflecting the relative danger of the agent(s) to laboratory personnel, the workplace environment, and the surrounding community. Associated with each biosafety level classification are certain design, operating, and personnel training measures — from standard microbiological practices and no special containment or design for BSL-1, to complete isolation with strict access control, separate ventilation and high-efficiency particulate air (HEPA) filters, personnel training, etc., for BSL-4. Here we focus on BSL-2, the most common design for large-scale pharmaceutical manufacturing plants.
机译:处理生物制剂(例如病原体或转基因生物)的任何制药机构都必须采取适当的生物防护措施。实验室和生产区域被指定为生物安全等级1至生物安全等级4(BSL-1至BSL-4),反映了试剂对实验室人员,工作场所环境和周围社区的相对危险。与每种生物安全级别分类相关的是某些设计,操作和人员培训措施-从标准的微生物实践,没有针对BSL-1的特殊遏制或设计到通过严格的访问控制,独立的通风和高效的颗粒空气(HEPA)完全隔离)过滤器,人员培训等,用于BSL-4。在这里,我们重点介绍BSL-2,这是大型制药厂最常用的设计。