Industry has been exposed to on line partial discharge (PD) technology, related to generators and motors, for many years. Recently introduced continuous on line predictive relays have extended the applications to include switchgear and cable. Mittal Steel Vanderbijlpark has invested in such a system for the on-line analysis of MV switchgear. Initial results clearly indicate that partial discharge analysis of MV switchgear is an excellent on-line predictive maintenance tool. The results also show that the key factors in implementing an on line partial discharge predictive maintenance program are to trend and not base decisions on individual or absolute values, and to correlate partial discharge activity against operating dynamics (humidity and temperature in the case of switchgear).
机译:多年来,工业界一直使用与发电机和电动机有关的在线局部放电(PD)技术。最近推出的连续在线预测继电器已将应用范围扩展到开关柜和电缆。 Mittal Steel Vanderbijlpark已投资用于中压开关柜在线分析的系统。初步结果清楚地表明,中压开关柜的局部放电分析是一种出色的在线预测维护工具。结果还表明,实施在线局部放电预测性维护程序的关键因素是趋向而非基于单个或绝对值做出决策,并且将局部放电活动与运行动态(在开关柜的情况下为湿度和温度)相关联。

著录项

  • 来源
    《Vector》 |2006年第2期|p.464850|共3页
  • 作者

    James Cowling;

  • 作者单位

    Martec and Meyer Naude, Mittal Steel Vanderbijlpark;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 发电、发电厂;
  • 关键词