The air void content of both in-place and laboratory-compacted hot-mix asphalt may be the factor that most affects the performance of a properly designed mixture. A mediocre mix, well constructed with good in-place air voids, often will perform better than a good mix that has been poorly constructed. In-place density may be monitored by using three methods: cores, nuclear density gauge measurements, and nonnuclear density gauge measurements. A study was done to evaluate and compare two non-nuclear density devices, the pavement quality indicator (PQI) Model 301 and the PaveTracker, to in-place core densities. Testing and analyses of 20 projects showed that unconnected gauge measurements (from each gauge) provided reasonable correlation (significant at a 5% level of significance) with core density measurements approximately 75% of the time. Average coefficients of determination for the relationships between uncor-rected gauge measurements and core densities were approximately .5. Simulation analyses indicated that the error in measuring in-place air voids using calibrated PQI Model 301 gauge measurements based on the constant offset method can be 1% to 2.7% air voids for the average of 10 measurements. The numerical experiments also indicated that calibration of PQI Model 301 by simple offset or by slope and offset did not improve the correlation between the gauge and core densities.
机译:就地和实验室压实的热混合沥青的气孔含量可能是最影响正确设计混合物性能的因素。中等结构的混合料,结构良好,内部有良好的空隙,通常会比结构较差的混合料更好。可以使用三种方法来监测就地密度:岩心,核密度仪测量和非核密度仪测量。进行了一项研究,以评估和比较两种非核密度设备(路面质量指标(PQI)301型和PaveTracker)与就地芯密度。对20个项目的测试和分析表明,未连接的仪表测量值(来自每个仪表盘)提供了合理的相关性(在5%的显着性水平下显着),并且芯密度测量值大约占时间的75%。未校正量规测量值与岩心密度之间关系的平均测定系数约为.5。仿真分析表明,对于基于10个测量值的平均值,使用基于恒定偏移量法的经过校准的PQI 301型仪表测量仪测量就地气隙时,误差可能为1%至2.7%。数值实验还表明,通过简单的偏移量或通过斜率和偏移量对PQI模型301进行校准并不能改善仪表密度和岩心密度之间的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号