【24h】

Design Process

机译:设计过程

获取原文
获取原文并翻译 | 示例
           

摘要

Following the Cardington tests, a number of simple structural models were developed which combine the residual strength of steel composite beams with the strength of the slab in fire. These models use the combined yield line and membrane action approach described in BRE Digest 462 to assess performance of a slab designed to generate tensile membrane action. Using these models, the designer is able to leave large numbers of secondary beams unprotected in buildings requiring 30 to 120 minutes fire resistance although some compensating features, such as increased mesh size and density, may be required.
机译:根据Cardington测试,开发了许多简单的结构模型,这些模型将钢复合梁的残余强度与楼板在火中的强度结合在一起。这些模型使用BRE Digest 462中描述的组合屈服线和膜作用方法来评估旨在产生拉伸膜作用的平板的性能。使用这些模型,设计人员可以在需要30至120分钟耐火性的建筑物中保留大量的次光束,尽管可能需要一些补偿功能,例如增加网格尺寸和密度。