Single storey buildings do not normally require structural fire resistance (and therefore fire protection) as Section 7.4 of Approved Document B (England and Wales) considers them to be structures that only support a roof and excludes them. Exceptions occur where an element of the structure provides support or stability to elements such as: 1. A separating wall 2. A compartment wall or the enclosing structure of a protected zone 3. An external wall that must retain stability to prevent fire spread to adjacent buildings (i.e. a boundary condition). The wall must achieve not only the required fire resistance period but also the insulation and integrity requirements too 4. A support to a gallery or a roof which also forms the function of a floor (e.g. a car park or a means of escape).
机译:单层建筑物通常不需要结构耐火性(并因此需要防火),因为批准的文件B(英格兰和威尔士)第7.4节认为它们是仅支撑屋顶且不包括屋顶的结构。当结构的一个元素为元素提供支撑或稳定性时,会发生例外情况:1.分隔墙2.隔室壁或保护区的封闭结构3.必须保持稳定性以防止火势蔓延到相邻区域的外壁建筑物(即边界条件)。墙不仅必须达到要求的耐火时间,而且还必须达到隔热和完整性要求。4.对走廊或屋顶的支撑,它也可以构成地板的功能(例如停车场或逃生通道)。