When considering whether steelwork that has been subject to fire can be re-used, a general rule of thumb is that if the steel is straight and there are no obvious distortions then it is probably still fit for purpose. At 600℃ the yield strength and stiffness of steel is equal to about 40% and 30% respectively of their room temperature values. Any steel still remaining straight after the fire and which had been carrying an appreciable load was probably not heated beyond 600℃, will not have undergone any metallurgical changes and will therefore be fit for re-use.
机译:在考虑是否可以重新使用遭受火灾的钢结构时,通常的经验法则是,如果钢是直的并且没有明显的变形,则可能仍然适合使用。在600℃时,钢的屈服强度和刚度分别等于其室温值的40%和30%。着火后仍保持直线状态且承受明显载荷的任何钢可能未加热到600℃以上,不会发生任何冶金变化,因此适合重新使用。