Long-distance pumping of concrete 2 076 meters (with relay pumps installed at two locations) was executed for the placement of invert concrete for the construction of a caisson for the Gotanda River Spillway Discharge Section ordered by Kawasaki City. Having quantified the required performance of concrete to be applied to long-distance pumping in the process of considering the mix proportions of the invert concrete, the authors focused on thixotropy as a factor that affects pumping load. Through laboratory tests and demonstration experiments, the use of AE and high-range water reducing agent with high dispersion effect retention and pumpability enhancing admixture were found to be effective for the reduction of thixotropy. Further, in actual construction, quality control was performed to suppress pipe blockages due to segregation and increased pumping load.%川崎市発注の五反田川放水路放流部函体築造工事のインバートコンクリートの施工において,配管実長2076m(中継ポンプ2カ所配置)の長距離圧送を実施した。筆者らは,インバートコンクリートの配合を検討するにあたって,長距離圧送に適用するコンクリートの要求性能を整理したうえで,圧送負荷に影響する要因としてチキソトロピー性に着目した。そして,室内試験および実証実験により,チキソトロピー性の低減には分散効果の保持性が高い高性能AE減水剤およびポンプ圧送助剤の使用が効果的であることを確認した。また,実施工では材料分離や圧送負荷の上昇による配管閉塞を抑制するための品質管理を実施した。
机译:川崎市下令向长城泵送2076米的混凝土(在两个位置安装了中继泵),用于倒置混凝土的放置,以建造五反田河溢洪道排放段沉箱。在考虑了倒置混凝土的混合比的过程中,量化了长距离泵送所需的混凝土性能后,作者将触变性作为影响泵送负荷的因素。通过实验室测试和演示实验,发现使用具有高分散效果保持性和泵送性增强混合物的AE和高范围减水剂可有效降低触变性。此外,在实际施工中,进行了质量控制,以防止由于偏析和泵送负荷增加而造成的管道堵塞。笔者らは,インバートコンクリートの配合を検探するにあたって,长距离圧送に适用するコンクリートの要求性能を整理したうえで,圧送负荷に影响する要因としてチキソトロピーそして,室内试験および実证実験により,チキソトロピー性の低减には分散效果の保持性が高い高效AE减水剤およびポンプ圧送助剤の使用が效果的であることを确认した。また,実施工では材料分离や圧送负荷の上升による配管闭塞を抑制するための品质管理を実施した。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号