An internally confined hollow RC (ICH RC) column offers strong and durable confinement owing to the reinforcement provided by the inner tube. The strength and ductility of the column are enhanced because of the continuous confining stress provided by the inner tube. The excellent structural performance of ICH RC columns makes them particularly suitable for applications in high-rise buildings. However, if a high-rise building is damaged by fire, it will collapse without fire resistance performance. Also, lack of evacuation measures endangers human life. Thus, to predict the status of structures in fires, their behaviour should be evaluated in terms of fire time. In this study, the fire resistance performance of an ICH RC column was analysed during an ISO 834 standard fire and with certain initial conditions. Furthermore, the effects of hollow ratio, thickness of inner tube and thickness of cover concrete on the fire resistance performance were analysed. The results could be used for designing fire-resistant ICH RC columns.
机译:由于内管的加强作用,内部受约束的空心RC(ICH RC)立柱提供了坚固耐用的约束。由于内管提供了连续的限制应力,因此提高了色谱柱的强度和延展性。 ICH RC柱的出色结构性能使其特别适用于高层建筑。但是,如果高层建筑被火灾损坏,则其坍塌而没有耐火性能。另外,疏散措施的缺乏也危及生命。因此,要预测火灾中建筑物的状态,应根据火灾时间评估其行为。在这项研究中,分析了ICH RC色谱柱在ISO 834标准火灾期间和某些初始条件下的耐火性能。此外,分析了空心比,内胎厚度和覆盖混凝土厚度对耐火性能的影响。结果可用于设计耐火ICH RC柱。

著录项

  • 来源
    《Structural concrete》 |2014年第4期|543-555|共13页
  • 作者单位

    Korea Inst Ocean Sci & Technol, Coastal Dev & Ocean Energy Res Div, Ansan 426744, South Korea;

    Korea Inst Ocean Sci & Technol, Coastal Dev & Ocean Energy Res Div, Ansan 426744, South Korea;

    Korea Inst Ocean Sci & Technol, Coastal Dev & Ocean Energy Res Div, Ansan 426744, South Korea;

    Korea Inst Ocean Sci & Technol, Coastal Dev & Ocean Energy Res Div, Ansan 426744, South Korea;

    Korea Inst Ocean Sci & Technol, Coastal Dev & Ocean Energy Res Div, Ansan 426744, South Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    fire resistance; composite column; concrete; ISO 834; Eurocode;

    机译:耐火性;复合柱;混凝土;ISO 834;欧洲规范;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号