...
首页> 外文期刊>Sensors and Actuators >Novel 'turn off-on' sensors for highly selective and sensitive detection of spermine based on heparin-quenching of fluorescence CdTe quantum dots-coated amphiphilic thiophene copolymers
【24h】

Novel 'turn off-on' sensors for highly selective and sensitive detection of spermine based on heparin-quenching of fluorescence CdTe quantum dots-coated amphiphilic thiophene copolymers

机译:基于荧光CdTe量子点涂层的两亲噻吩共聚物的肝素猝灭,用于高选择性和灵敏检测精胺的新型“关闭”传感器

获取原文
获取原文并翻译 | 示例
           

摘要

Graphical abstractDisplay OmittedHighlightsNovel CdTe QDs coated with amphiphilic conjugated polythiophenes were developed.Highly fluorescent P1QDs and P2QDs (QY, 63% and 78%) were used as “turn off–on” sensors.The sensors show highly selective and sensitive responses to heparin and spermine.The sensors were successfully applied to detect heparin and spermine in human serum.AbstractNovel “turn off-on” optosensors based on amphiphilic thiophene copolymers coated CdTe quantum dots (P1QDs and P2QDs) were developed for the dual detection of heparin and spermine. The emission of the P1QDs and P2QDs is found to be quenched in the presence of heparin by electron transfer mechanism through electrostatic and hydrogen bonding interactions. Upon the addition of spermine, heparin has been removed from the surface of P1QDs and P2QDs due to the strong electrostatic interactions between spermine and heparin, which showed significant fluorescence recovery of the sensors. Under optimum conditions, both P1QDs and P2QDs sensors displayed excellent limits of detection for heparin of 1.59nmolL−1(R2=0.9955) and 0.88nmolL−1(R2=0.9908) with linear ranges of 1–11μmolL−1and 1–10μmolL−1, respectively. P1QDs and P2QDs also showed remarkable limits of detection for spermine of 2.90nmolL−1(R2=0.9957) and 1.66nmolL−1(R2=0.9928) with linear ranges of 0.05–15μmolL−1and 1–12μmolL−1, respectively. The P1QDs and P2QDs sensors show a high selectivity to heparin and spermine over common interfering substances and ions. In addition, the proposed method was successfully utilized in serum samples, which could facilitate the further heparin and spermine biochemical and biomedical research.
机译: 图形摘要 < ce:simple-para>省略显示 突出显示 涂覆了新型CdTe量子点 使用高度荧光的P1QD和P2QD(QY,分别为63%和78%)作为“ t 这些传感器对肝素和精胺显示出高度选择性和敏感性。 < ce:label>• 这些传感器已成功应用于人体血清中肝素和精胺的检测。 摘要 小说“转向开发了基于两亲噻吩共聚物涂层的CdTe量子点(P1QD和P2QD)的“ on-on”光电传感器,用于肝素和精胺的双重检测。发现P1QDs和P2QDs的发射在肝素存在下通过电子转移机制通过静电和氢键相互作用而被猝灭。加入精胺后,由于精胺和肝素之间的强静电相互作用,肝素已从P1QD和P2QDs的表面上去除,这表明传感器具有显着的荧光恢复性。在最佳条件下,P1QD和P2QDs传感器均显示出极佳的肝素1.59nmolL -1 (R 2 = 0.9955)和0.88nmolL − 1 (R 2 = 0.9908)的线性范围为1–11μmolL − 1 和1–10μmolL − 1 ,分别。 P1QD和P2QD还显示出2.90nmolL -1 (R 2 = 0.9957)和1.66nmolL − 1 (R 2 = 0.9928)具有线性范围分别为0.05–15μmolL -1 和1–12μmolL -1 。 P1QD和P2QDs传感器对肝素和精胺比普通干扰物质和离子具有高选择性。此外,该方法已成功应用于血清样品中,可进一步促进肝素和精胺的生化和生物医学研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号