首页> 外文期刊>Sensors and Actuators >A facile one-step gold nanoparticles enhancement based on sequential patterned lateral flow immunoassay device for C-reactive protein detection
【24h】

A facile one-step gold nanoparticles enhancement based on sequential patterned lateral flow immunoassay device for C-reactive protein detection

机译:基于顺序图案化横向流动免疫测量装置的C反应蛋白检测的容易一步金纳米颗粒增强

获取原文
获取原文并翻译 | 示例
           

摘要

A gold nanoparticles (AuNPs) enhancement strategy for lateral flow immunoassays (LFIAs) was previously reported to improve assay sensitivity. The multi-steps of detection resulted in a tedious procedure. In this report, to reduce this limitation, a sequential flow LFIA was introduced to perform the AuNPs enhancement in only single step operation using C-reactive protein (CRP) as a model analyte. The delay and non-delay channels created on nitrocellulose membrane (NCM) using wax-printing method were used to deliver immunoassay and AuNPs enhancement reagents to the detection zone sequentially. For the enhancing step, AuNPs were enlarged by the catalytic reaction of KAuCl_4 and NH_2OHHC1. Under optimal conditions, a calibration curve was found in a range of 0.1-5 μg·mL~(-1) with a good linear correlation (R~2 = 0.9953). The limits of detection (LOD) were found to be 0.1 and 0.001 μg·mL~(-1) for naked eye observation and calculation (3SD/slope), respectively. Furthermore, the device shows no cross-reactivity with common interferences for CRP. The platform was successfully applied to detect CRP in certified human serum samples within 15 min, demonstrating the simplicity and speed of the AuNPs enhancement strategy platform. These promising results suggest that the new device may be used as an alternative tool for CRP detection and other biomarkers for POCT analysis.
机译:先前据报道了一种用于横向流动免疫测定(LFIAS)的金纳米颗粒(AUNP)增强策略以提高测定敏感性。检测的多步骤导致繁琐的过程。在本报告中,为了减少这种限制,引入了顺序流动LFIa以使用C反应蛋白(CRP)作为模型分析物的单步操作仅在单步操作中进行AUNPS增强。使用蜡印刷方法在硝酸纤维素膜(NCM)上产生的延迟和非延迟通道用于顺序向检测区递送免疫测定和AUNPS增强试剂。对于增强步骤,通过KauCl_4和NH_2OHHC1的催化反应扩大了AUNP。在最佳条件下,校准曲线在0.1-5μg·ml〜(-1)的范围内,线性相关性良好(R〜2 = 0.9953)。发现检测限(LOD)为肉眼观察和计算(3SD /斜率)为0.1和0.001μg·ml〜(-1)。此外,该装置没有对CRP的常见干扰没有交叉反应性。该平台在15分钟内成功应用于检测CRP在经过认证的人体血清样品中,展示了AUNPS增强策略平台的简单性和速度。这些有希望的结果表明,新设备可以用作CRP检测和其他生物标志物的替代工具,用于POCT分析。

著录项

  • 来源
    《Sensors and Actuators》 |2021年第2期|129241.1-129241.9|共9页
  • 作者单位

    Program in Biotechnology Faculty of Science Chulalongkorn University 254 Phayathai Road Patumwan Bangkok 10330 Thailand Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE) Department of Chemistry Faculty of Science Chulalongkorn University 254 Phayathai Road Patumwan Bangkok 10330 Thailand;

    Department of Clinical Chemistry Faculty of Medical Technology Mahidol University 999 Phutthamonthon 4 Road Salaya Nakhon Pathom 73170 Thailand;

    Institute of Biotechnology and Genetic Engineering Chulalongkorn University Bangkok 10330 Thailand;

    Institute of Biotechnology and Genetic Engineering Chulalongkorn University Bangkok 10330 Thailand;

    Departments of Chemistry and Chemical and Biological Engineering Colorado State University Fort Collins Colorado 80523 United States;

    Department of Microbiology Faculty of Science Chulalongkorn University 254 Phayathai Road Patumwan Bangkok 10330 Thailand;

    Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE) Department of Chemistry Faculty of Science Chulalongkorn University 254 Phayathai Road Patumwan Bangkok 10330 Thailand;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Sequential patterned lateral flow immunoassay; Gold nanoparticles enhancement; C-reactive protein;

    机译:顺序图案化横向流动免疫测定;金纳米粒子增强;C-反应蛋白;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号