Influence of solar photovoltaic array on operation of grid-interactive fifteen-level modular multilevel converter with emphasis on power quality

机译:太阳能光伏阵列对电网互动式十五级模块化多级变换器运行的影响(重点是电能质量)

获取原文
获取原文并翻译 | 示例
           

摘要

This paper unveils an operational impact of variable Solar Photovoltaic (SPV) array into 15-level single-stage Modular Multilevel Converter (MMC) thyristorized operated system. A MMC system is developed in which the working of three sub-system modules has been coordinated at a Point of Common Coupling (PCC). In addition, each of 15-level sub-system has been operated at a Resistance Inductance (RL) and a SPV array load. Furthermore, the investigation of DC power inversion into AC power has been elaborated by varying the switching angles of thyristors from 100(omicron) to 180(omicron) for an individual module. The operation of MMC system has been coordinated with Dynamic Voltage Restorer (DVR), where its performance has been estimated during grid faults under unity power factor conditions. Especially, the investigation on Power Quality (PQ) has been highlighted at PCC by operating with proportional integral and fuzzy logic controlled DVR. It has been verified that response with fuzzy logic DVR scheme is able to control the unbalanced conditions, under steady-state and transient conditions effectively. The effectiveness of the proposed controller is demonstrated by using standard IEEE-519/1547, which stipulates that harmonic level in utility injected current by any SPV source cannot exceed 5%. Therefore, a reduction in harmonics and DC offset is ensured satisfactorily, among all variables at PCC according to IEEE-519/1547 standard at fundamental frequency.
机译:本文揭示了可变太阳能光伏(SPV)阵列对15级单级模块化多电平转换器(MMC)晶闸管操作系统的运行影响。开发了一个MMC系统,其中三个子系统模块的工作已在公共耦合点(PCC)进行了协调。此外,15级子系统中的每个子系统都已在电阻电感(RL)和SPV阵列负载下运行。此外,对于单个模块,已经通过将晶闸管的开关角从100(微米)改变为180(微米)来详细研究将直流功率转换为交流功率。 MMC系统的运行已与动态电压恢复器(DVR)进行了协调,该系统已在单位功率因数条件下的电网故障期间评估了其性能。特别是,在PCC上,通过与比例积分和模糊逻辑控制的DVR一起工作,对电能质量(PQ)的研究得到了重视。验证了模糊逻辑DVR方案的响应能够有效地控制稳态和瞬态条件下的不平衡条件。建议的控制器的有效性通过使用标准IEEE-519 / 1547进行了证明,该标准规定,任何SPV电源在公用事业注入电流中的谐波电平不得超过5%。因此,在根据IEEE-519 / 1547标准在PCC的所有变量中,基本频率下的谐波和DC偏移的降低都令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号