The wind speed distribution and wind energy potential are investigated in three selected locations in Oyo state using wind speed data that span between 12 and 20 years measured at 10 m height. In addition, the performance of selected small to medium size wind turbines in these sites were examined. The annual energy output and capacity factor for these turbines were determined. It was found that the monthly mean wind speeds in Oyo state ranges from 2.85 m/s to 5.20 m/s. While the monthly mean power density varies between 27.08 W/m~2 and 164.48 W/m~2, while the annual mean power density is in the range of 67.28 W/m~2 and 106.60 W/m~2. Based on annual energy output, wind turbines with cut-in wind speed of about 2.5 m/s and moderate rated wind speeds will be best suited for all the sites.
机译:使用在10 m高度测量的跨度为12到20年的风速数据,在奥约州的三个选定位置研究了风速分布和风能潜力。此外,还检查了这些站点中选定的中小型风力涡轮机的性能。确定了这些涡轮机的年度能量输出和容量因子。据发现,奥约州的月平均风速为2.85 m / s至5.20 m / s。月平均功率密度在27.08 W / m〜2和164.48 W / m〜2之间变化,而年平均功率密度在67.28 W / m〜2和106.60 W / m〜2之间。根据年发电量,切入风速约为2.5 m / s且额定风速适中的风力涡轮机将最适合所有场所。

著录项

  • 来源
    《Renewable energy》 |2011年第12期|p.3297-3304|共8页
  • 作者

    M.S. Adaramola; O.M. Oyewola;

  • 作者单位

    Department of Energy and Process Engineering, Norwegian University of Science and Technology, Trondheim, Norway;

    Department of Mechanical Engineering, University oflbadan, Ibadan, Nigeria;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    wind speed; energy output; capacity factor; wind turbine; nigeria;

    机译:风速能量输出容量系数风力发电机尼日利亚;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号