Interventional radiology procedures have always been of particular concern because of the potential high dose to the workers. Special attention has recently been given to the lens dose: in 2011 the ICRP issued the recommendation 'Statement on Tissue Reactions' where a new limit of 20 mSv in a year, averaged over defined periods of 5 years, is given. Due to the impossibility of measuring the dose directly on the eye, there is not still a general consensus on a standardized methodology to assess the lens dose, which should be at the same time reliable, robust and simple to implement in practice. The procedure described here aims to assess the lens dose using the Hp(0.07) equivalent dose measured with a dosimeter worn at chest level above the lead apron, through a correlation with the total KAP per procedure and considering the type of the protection tools used during each procedure: glasses (with lateral shields), ceiling screen, both or neither of them and the frequency of their use.
机译:由于对工人的潜在高剂量,介入放射学程序一直受到特别关注。最近特别注意了晶状体的剂量:2011年,ICRP发布了“组织反应声明”建议,其中给出了新的每年20 mSv的限值,在定义的5年中平均。由于不可能直接在眼睛上测量剂量,因此对于评估晶状体剂量的标准化方法尚无普遍共识,同时应在实践中可靠,可靠且易于实现。此处介绍的程序旨在通过与铅含量高于每围手术程序的KAP的相关性并考虑在使用过程中使用的保护工具的类型,使用Hp(0.07)当量剂量评估镜片的剂量,当量剂量计应佩戴在铅围裙上方的胸部水平处。每种程序:眼镜(带侧护罩),天花屏,两者或两者都不使用以及使用频率。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2018年第1期|95-100|共6页
  • 作者单位

    Radiological Department, Bressanone Hospital, Azienda Sanitaria dell'Alto Adige, Bressanone-Brixen, Italy;

    Faculty of Medicine, School for Radiographers, University of Udine, Udine, Italy;

    Medical Physics Department, Academic Hospital 'S.Maria della Misericordia', Udine, Italy;

    Medical Physics Department, Academic Hospital 'S.Maria della Misericordia', Udine, Italy;

    Medical Physics Department, Academic Hospital 'S.Maria della Misericordia', Udine, Italy;

    Radiation Protection Office, University Hospital Center 'Mother Theresa', Tirana, Albania;

    Interventional Radiology Department, Academic Hospital 'S.Maria della Misericordia', Udine, Italy;

    Interventional Radiology Department, Academic Hospital 'S.Maria della Misericordia', Udine, Italy;

    Hamad Medical Corporation, Doha, Quatar;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号