首页> 外文期刊>Progress in Structural Engineering and Materials >Tension development length and lap splice design for reinforced concrete members
【24h】

Tension development length and lap splice design for reinforced concrete members

机译:钢筋混凝土构件的拉力发展长度和搭接设计

获取原文
获取原文并翻译 | 示例
           

摘要

The key factors that govern development (anchorage) and splice performance of reinforcing bars in tension are described. The bond design provisions of the AASHTO (American Association of State Highway and Transportation Officials) LRFD (Load and Resistance Factor Design) Bridge Design Specifications, the American Concrete Institute Building Code Requirements for Structural Concrete (ACI 318-05), ACI Committee 408, CEB-FIP Model Code 1990, and Eurocode 2 are summarized and compared with test results. In terms of the key factors, the bond strength of bars not confined by transverse reinforcement is proportional to the concrete compressive strength to the 1/4 power. The contribution of transverse reinforcement to bond strength increases with the area of the transverse reinforcement per bar and the relative rib area and diameter of the bar being developed or spliced and has been found to be proportional to the concrete compressive strength to a power between 3/4 and 1.0. For deep members or for high-slump (conventional and superplasticized) concrete, the effect of bar placement may be greater than accounted for in current design provisions. Of the five design procedures compared in this paper, those developed by ACI Committee 408 provide the best match with test results for both developed and spliced bars. For developed bars, the other four design procedures result in a high percentage of tests for which the test to calculated strength ratios (T/C) are less than 1.0, with the greatest percentage of low T/C values resulting from the AASHTO requirements. The relative safety of the latter four design procedures improves for lap splices. A provision in ACI 318-05 that allows a 20% reduction in development and lap splice length for bars smaller than 19 mm appears to be unsafe and should be removed or modified.
机译:描述了控制钢筋拉伸的发展(锚固)和拼接性能的关键因素。 AASHTO(美国国家公路和运输官员协会)LRFD(荷载和阻力系数设计)桥梁设计规范,美国混凝土协会《建筑混凝土结构规范要求》(ACI 318-05),ACI委员会408,总结了CEB-FIP模型代码1990和欧洲代码2,并与测试结果进行了比较。在关键因素方面,不受横向钢筋限制的钢筋粘结强度与混凝土的抗压强度成正比,为1/4的幂。横向钢筋对粘结强度的贡献随着每根钢筋的横向钢筋面积以及钢筋的相对肋骨面积和直径的增大或拼接而增加,并且已经发现,混凝土的抗压强度与混凝土的抗压强度成正比,介于3 / 4和1.0。对于深构件或高坍落度(常规和超塑化)混凝土,钢筋放置的影响可能大于当前设计规定中的考虑。在本文比较的五种设计程序中,由ACI委员会408开发的程序与已开发和拼接的钢筋的测试结果最匹配。对于发达的钢筋,其他四种设计程序会导致较高的测试百分比,其测试强度与计算得出的强度比(T / C)小于1.0,而最大的低T / C值百分比则来自AASHTO要求。后四个设计程序的相对安全性提高了搭接接头的安全性。 ACI 318-05中的一项规定允许小于19 mm的钢筋的展开和搭接长度减少20%,这似乎是不安全的,应将其删除或修改。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号