摘要

To meet the domestic demand of software autonomous scheduling, Xi'an Jiaotong University had developed MIDAC (a Module In-vessel degraded severe accident Analysis Code) which can not only analyze the processes of in-vessel severe accident, but also provide the related results of each one. This code was composed of five modules: the early behavior module, the core degradation module, the debris bed module, the melting materials IVR module and the connecting module. In this paper, the basic mathematic-physical models of those modules were briefly introduced. Then, the CPR1000 station blackout scenario severe accident was set as an example to calculate the primary system thermal-hydraulic transient, the core degradation and the debris behavior, as well as the creep rupture of heat structures in primary loop pressure boundary. At last, the accuracy of MIDAC was verified in partial comparison with SCDAP/RELAP5 in primary system thermal-hydraulic transient analyzing part. (C) 2014 Elsevier Ltd. All rights reserved.
机译:为满足国内软件自主调度的需求,西安交通大学开发了MIDAC(模块式车内降级严重事故分析程序),该程序不仅可以分析车内严重事故的过程,而且可以提供相关的结果。每个。该代码由五个模块组成:早期行为模块,岩心退化模块,碎屑床模块,熔融材料IVR模块和连接模块。在本文中,简要介绍了这些模块的基本数学物理模型。然后,以CPR1000站停电情景严重事故为例,计算一次系统的热液瞬变,岩心退化和碎屑行为,以及一次回路压力边界内热结构的蠕变破裂。最后,在一次系统热工水力暂态分析部分,通过与SCDAP / RELAP5的部分比较,验证了MIDAC的准确性。 (C)2014 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Progress in Nuclear Energy》 |2014年第9期|44-54|共11页
  • 作者单位

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    MIDAC; CPR1000; Station blackout scenario;

    机译:MIDAC;CPR1000;车站停电情况;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号