In August 2018, a fire badly damaged a listed building in the centre of Belfast. This left the perimeter walls standing and the inside largely destroyed. Because of the dangerous nature of the structure, the surrounding area was closed. This paper describes the engineering aspects of the approach to making the remaining structure safe to allow the surrounding area to reopen and to start the rebuilding works on the retained building. The design approach to the public safety cordon involved the use of empirical techniques, as well as advanced simulation software. The design approach for the facade-retention scheme was complicated by the poor ground and buried services, as well as having to allow for installation with no access inside the building. The solution involved the use of shipping containers as structural components, as well as fibre-reinforced foundation rafts. The scheme has been successfully installed, and access to the city centre has been reinstated.
机译:2018年8月,火灾严重损坏了贝尔法斯特中心的上市大楼。这让周边墙壁站立,内部大部分摧毁。由于结构的危险性,周围区域被关闭。本文介绍了制造剩余结构安全的方法的工程方面,以便允许周围区域重新开放并开始重建在保留的建筑物上。公共安全警戒线的设计方法涉及使用实证技术,以及先进的仿真软件。外立保留方案的设计方法对贫困地面和埋地服务复杂,并且必须允许在建筑物内部进行安装。该解决方案涉及使用运输容器作为结构部件,以及纤维增强基础筏。该方案已成功安装,并恢复了城市中心的访问。