A research programme has been commenced which is designed to determine the mechanisms of electric breakdown in insulating liquids under various conditions. The paper describes experimental equipment and techniques, and some results which have been obtained on transformer oil. Special equipment includes a transparent pressure chamber with an internal glass test-vessel, which enables the liquid under test to be subjected to hydrostatic pressures up to 500 lb/in2 and voltages up to 100 kV peak. A protective circuit hasbeen developed, incorporating triggered spark-gap, which limits the duration of breakdown currents to a few microseconds. A wide range of breakdown strengths has been obtained, varying from 5 000 kVpeak/cm with 1-microsec impulses, to below 100 kV(r.m.s.)/cm for a fibre contaminated oil under a.c. test conditions. The removal of fibres raises the a.c. strength of otherwise untreated oil to 400 kV(r.m.s.)/cm. It is concluded that a breakdown mechanism initiated by cavitation is operative in certain circumstances.
机译:已经开始了一项研究计划,旨在确定各种条件下绝缘液体中的电击穿机理。本文介绍了实验设备和技术,以及在变压器油上获得的一些结果。特殊设备包括带有内部玻璃测试容器的透明压力室,该透明压力室使被测液体能够承受高达500 lb / in2的静水压力和高达100 kV峰值的电压。已经开发出一种保护电路,该电路结合了触发式火花隙,可将击穿电流的持续时间限制在几微秒内。已经获得了广泛的击穿强度,从1毫秒脉冲的5000 kVpeak / cm到交流电下纤维污染的油的100 kV(r.m.s。)/ cm以下。测试条件。纤维的去除提高了交流电否则未经处理的油的强度可达400 kV(r.m.s。)/ cm。结论是,在某些情况下,由气蚀引发的分解机制是有效的。