Figures 1 and 2 show two images of the same problem: one x-ray, the other optical. In both cases it's the result of sulphur corrosion on the surface of copper and silver surfaces. Both surfaces remain exposed after a soldering operation, and in the presence of sulphur, it is possible to witness corrosion. In time it can result in an open connection, as the figures show. Figure 1, taken on a Dage x-ray system, shows different degrees of corrosion on the tracking just below the solder joint fillet. In failure investigations it's important to see and record as much as possible without change or damage to the sample. On one joint there was an open connection on this QFP device.
机译:图1和2显示了相同问题的两个图像:一个是X射线,另一个是光学。两种情况都是铜和银表面硫腐蚀的结果。焊接操作后,两个表面均保持裸露状态,并且在存在硫的情况下,有可能发生腐蚀。如图所示,它会及时导致连接断开。在Dage X射线系统上拍摄的图1显示了在焊点圆角下方的走线上不同程度的腐蚀。在故障调查中,重要的是要尽可能多地查看和记录,而不会改变或损坏样本。在该QFP设备的一个关节上有一个开放的连接。