...
首页> 外文期刊>IEEE Transactions on Power Delivery >Design of a combined digital global differential and volt/hertz relay for step-up transformers
【24h】

Design of a combined digital global differential and volt/hertz relay for step-up transformers

机译:组合数字全局差分和伏特/赫兹继电器的设计,用于升压变压器

获取原文
获取原文并翻译 | 示例
           

摘要

The author presents the specifications and design principles of a digital relay covering the global differential and volt/hertz functions for a generator step-up transformer unit. It is the second and last relay developed in the project for an integrated digital generator protection system at Hydro-Quebec. The design of this system is based on a number of premises: use of low-cost standard bus cards together with digital signal processors to achieve sufficient computing power, grouping of many protection functions in the same independent crate, and implementation of functional redundancy by distribution of the same function between at least two independent crates. It is estimated that the ultimate systems will cost less than existing generator protection systems and offer substantial benefits.
机译:作者介绍了数字继电器的规格和设计原理,该数字继电器涵盖了发电机升压变压器单元的全局差分和伏特/赫兹功能。这是该项目中为魁北克水电开发的集成数字发电机保护系统开发的第二个也是最后一个继电器。该系统的设计基于多个前提:使用低成本标准总线卡以及数字信号处理器以实现足够的计算能力,将多个保护功能组合在同一独立的包装箱中,并通过分配实现功能冗余至少两个独立的板条箱之间具有相同的功能。据估计,最终系统的成本将低于现有的发电机保护系统,并提供大量收益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号