CAP88-PC, Version 2.0, and NORMTRI, which are based on the Gaussian plume model, were used to estimate the chronic dose due to a continuous, ground-level, atmospheric release of tritium as tritiated water. For the same conditions the predictions of CAP88-PC were found to be higher by a factor of 3 or less than those of NORMTRI. The major differences are due to the use of higher dose coefficients in CAP88-PC and NORMTRI's method of calculating the tritium content of food.
机译:基于高斯羽流模型的CAP88-PC,2.0版和NORMTRI被用于估算由于dose气在地面连续不断地向大气中释放而引起的慢性剂量。在相同条件下,发现CAP88-PC的预测比NORMTRI的预测高3倍或更少。主要差异是由于在CAP88-PC中使用了更高的剂量系数,以及NORMTRI的计算食物中content含量的方法。