首页> 外文期刊>Nuclear Technology >MONTE CARLO ASSESSMENTS OF ABSORBED DOSES TO THE HANDS OF RADIOPHARMACEUTICAL WORKERS DUE TO PHOTON EMITTERS
【24h】

MONTE CARLO ASSESSMENTS OF ABSORBED DOSES TO THE HANDS OF RADIOPHARMACEUTICAL WORKERS DUE TO PHOTON EMITTERS

机译:光发射器对放射性药物工作人员的吸收剂量的蒙特卡洛评估

获取原文
获取原文并翻译 | 示例
           

摘要

This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters that are used to show compliance with applicable regulations may overestimate or underestimate radiation doses to the skin depending on the nature of the particular procedure and the radionuclide being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations ofrnrealistic configurations typical for workers handling ra-diopharmaceuticals were performed for a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from dosimeter readings when dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.
机译:本文描述了放射性药物处理对核医学技术人员的辐射剂量的特征。使用环形剂量计进行辐射监测表明,根据特定程序的性质和所处理的放射性核素,用于证明符合适用法规的手指剂量计可能会高估或低估对皮肤的辐射剂量。为了更好地理解控制吸收剂量分布的参数,创建了一个详细的手模型,并将其用于所选核医学程序的蒙特卡洛模拟中。针对各种源光子的能量,进行了典型的逼真的配置的仿真,该配置针对于操作放射性药物的工人。缺乏带电粒子平衡,需要进行完整的光电子耦合传输计算。结果表明,当剂量计位于手指根部时,对手指不同区域的剂量可能与剂量计读数有显着差异。我们试图确定将实际剂量与剂量计读数相关的一致模式。这些模式取决于特定的工作条件,可用于更好地评估暴露于皮肤不同区域的吸收剂量。

著录项

  • 来源
    《Nuclear Technology》 |2009年第1期|164-168|共5页
  • 作者单位

    Oak Ridge National Laboratory Nuclear Science and Technology Division, P.O. Box 2008, Building 5700 Oak Ridge, Tennessee 37831-6170;

    Oak Ridge National Laboratory Nuclear Science and Technology Division, P.O. Box 2008, Building 5700 Oak Ridge, Tennessee 37831-6170;

    Nuclear Regulatory Commission, Washington, D.C. 20555-0001;

    Nuclear Regulatory Commission, Washington, D.C. 20555-0001;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    extremity monitoring; radiopharmacy; Monte Carlo;

    机译:肢体监测;放射药学蒙特卡洛;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号