首页> 外文期刊>Nuclear Technology >EURISOL MULTIMEGAWATT TARGET UNIT-MAFF CONFIGURATION: DOSIMETRY AND ACTIVATION STUDIES
【24h】

EURISOL MULTIMEGAWATT TARGET UNIT-MAFF CONFIGURATION: DOSIMETRY AND ACTIVATION STUDIES

机译:EURISOL MULTIMEGAWATT目标单位-MAFF配置:文档和激活研究

获取原文
获取原文并翻译 | 示例
           

摘要

The EURopean Isotope Separation On-Line Radioactive Ion Beam (EURISOL) project aims at building a facility to produce radioactive ion beams with intensities two to three orders of magnitude higher than those presently available. A 4-MW (1-GeV, 4-mA) proton beam hits a liquid mercury converter, generating, by spoliation reactions, high neutron fluxes that induce fission in surrounding fissile targets. In this work, Monte Carlo calculations of dose rate and activation were carried out to identify the necessary shielding and access restrictions for each section of the facility, including main- tenance, storage, and remote control spaces. These calculations allowed an optimization of the materials chosen for the assembly, based on the radioprotection issues, while taking into account the desired performance of the system. The results of the design studies indicate that the intended performance parameters (namely neutron fluxes, fission rates, and easy fission target manipulation) of the EURISOL multimegawatt target station are in reach. The safety analysis indicates that some regions of the facility need special attention from the safety and radioprotection points of view.
机译:欧洲同位素分离在线放射性离子束(EURISOL)项目旨在建立一个设施,以生产强度比目前可用的放射性离子束高2至3个数量级的放射性离子束。 4-MW(1-GeV,4-mA)质子束撞击液化汞转换器,通过水蚀反应产生高中子通量,从而引起周围裂变目标发生裂变。在这项工作中,对剂量率和激活率进行了蒙特卡洛计算,以确定该设施各部分(包括维护,存储和遥控空间)的必要屏蔽和访问限制。这些计算允许基于辐射防护问题优化用于组装的材料,同时考虑到系统的期望性能。设计研究的结果表明,EURISOL兆瓦级目标站的预期性能参数(即中子通量,裂变速率和易裂变目标操纵)已达到。安全分析表明,从安全和辐射防护的角度来看,设施的某些区域需要特别注意。

著录项

  • 来源
    《Nuclear Technology》 |2011年第2期|p.445-449|共5页
  • 作者单位

    Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953, Sacavem, Portugal;

    Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Lagnaro Viale dell'Universita, 2-35020 Legnaro (PD), Italy;

    CEA-Saclay, DSM/IRFU/SPHN, F-91191 Gif-sur-Yvette, France;

    CEA-Saclay, DSM/IRFU/SPHN, F-91191 Gif-sur-Yvette, France;

    Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953, Sacavem, Portugal;

    CERN, CH-1211, Geneve 23, Switzerland;

    CERN, CH-1211, Geneve 23, Switzerland;

    National Institute of Physics and Nuclear Engineering, Str. Atomistilor no. 407 P.O. Box MG-6, Bucharest - Magurele, Romania;

    National Institute of Physics and Nuclear Engineering, Str. Atomistilor no. 407 P.O. Box MG-6, Bucharest - Magurele, Romania;

    Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953, Sacavem, Portugal;

    Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Lagnaro Viale dell'Universita, 2-35020 Legnaro (PD), Italy;

    Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953, Sacavem, Portugal;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    radiation protection and safety; radioactive ion beams; eurisol multimegawatt target station;

    机译:辐射防护和安全;放射性离子束;eurisol兆瓦目标站;