首页> 外文期刊>Nuclear Technology >EARLY PHASE ACCIDENT PROGRESSION ANALYSIS OF FUKUSHIMA DAIICHI UNIT 3 BY THE SAMPSON CODE
【24h】

EARLY PHASE ACCIDENT PROGRESSION ANALYSIS OF FUKUSHIMA DAIICHI UNIT 3 BY THE SAMPSON CODE

机译:利用Sampson规则对福岛大地3号机组的早期事故进行分析

获取原文
获取原文并翻译 | 示例
           

摘要

Because of the high-magnitude earthquake and consequent tsunami that struck the east coast of Japan on March 11, 2011, at 14:46, Tokyo Electric Power Company's Fukushima Daiichi nuclear power plant experienced station blackout (SBO) resulting in a nuclear accident unprecedented in time and extent. Simulation of such an accident by means of computer codes is largely dependent on the applied boundary conditions and physical models. However, still-unknown boundary conditions and unclear phenomena result in uncertain computed quantities. In this study, first, the boundary conditions of emergency systems are theoretically derived, starting from a discussion of the reactor available measured quantities and related uncertainties. Then, newly implemented physical models (e.g., wetwell condensation mechanism), which were not accounted for in historical studies of long-term SBOs, are explained. As an early method for accident clarification and explanation regarding effective boundary conditions, results from the SAMPSON severe accident code were compared with theoretical values. The results of SAMPSON compared with the measured quantities available have shown that despite successful safety operations performed by the plant operators in Fukushima Daiichi Unit 3, the eventual lack of batteries (for systems operation and measurement reading) led to plant conditions of low core water level at high pressure, nullifying the attempt of the subsequent alternative water injection to prevent core degradation.
机译:由于2011年3月11日14:46袭击日本东海岸的强烈地震和随之而来的海啸,东京电力公司的福岛第一核电站经历了停电(SBO),导致史无前例的核事故。时间和范围。通过计算机代码对此类事故的模拟在很大程度上取决于所应用的边界条件和物理模型。但是,仍然未知的边界条件和不清楚的现象导致不确定的计算量。在这项研究中,首先,从对反应堆可用测量数量和相关不确定性的讨论开始,理论上推导出了应急系统的边界条件。然后,说明了在长期SBO的历史研究中未考虑的新实现的物理模型(例如,湿井凝结机理)。作为澄清和解释有效边界条件的一种早期方法,将SAMPSON严重事故代码的结果与理论值进行了比较。 SAMPSON的结果与所测得的数量进行比较表明,尽管福岛第一核电站3号机组的操作员成功进行了安全操作,但最终缺少电池(用于系统操作和测量读数)导致了低核心水位的工厂条件在高压下,可以避免后续注水以防止岩心退化的尝试。

著录项

  • 来源
    《Nuclear Technology》 |2014年第2期|241-254|共14页
  • 作者单位

    The Institute of Applied Energy, 1-14-2 Nishi-Shimbashi, Minato-Ku, Tokyo 1050003 Japan;

    The Institute of Applied Energy, 1-14-2 Nishi-Shimbashi, Minato-Ku, Tokyo 1050003 Japan;

    The Institute of Applied Energy, 1-14-2 Nishi-Shimbashi, Minato-Ku, Tokyo 1050003 Japan;

    The Institute of Applied Energy, 1-14-2 Nishi-Shimbashi, Minato-Ku, Tokyo 1050003 Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Fukushima Daiichi; boundary conditions; SAMPSON severe accident code;

    机译:福岛第一;边界条件;桑普森严重事故代码;