首页> 外文期刊>Nuclear science and engineering >Recent Progress in the Design of a Tomographic Device for Measurements of the Three-Dimensional Pin-Power Distribution in Irradiated Nuclear Fuel Assemblies
【24h】

Recent Progress in the Design of a Tomographic Device for Measurements of the Three-Dimensional Pin-Power Distribution in Irradiated Nuclear Fuel Assemblies

机译:测量辐射核燃料组件中三维销功率分布的层析成像设备设计的最新进展

获取原文
获取原文并翻译 | 示例
           

摘要

A tomographic technique for determination of the thermal power distribution in nuclear fuel assemblies is under development. The purpose is to provide an experimental validation tool for core simulation codes. Such codes are essential for the operation of nuclear power reactors, and validation is important in the process of improving and developing the codes as well as the fuel.rnThe tomographic method is nonintrusive and offers large amounts of data within a normal revision shutdown. In earlier experimental investigations using a test platform, the method proved useful, demonstrating results of satisfying quality. However, the measuring setup also revealed nonfeasible properties related to transport, decontamination, and background radiation shielding.rnIn this paper, the design of a new measuring device is presented. It is based on experiences from the test platform, but its size and weight make it advantageous regarding transports and decontamination. Moreover, the design inherently allows for more efficient background shielding.rnThe latter has been investigated in a detailed study using the MCNP simulation code. The results confirm the high levels of background radiation observed in the test platform. It is also concluded that the shielding properties in the new design are sufficient.
机译:用于确定核燃料组件中的热功率分布的层析成像技术正在开发中。目的是为核心仿真代码提供实验验证工具。此类代码对于核动力反应堆的运行必不可少,并且在改进和开发代码以及燃料的过程中进行验证非常重要。断层扫描方法是非侵入性的,并且在正常修订停工期间可提供大量数据。在较早的使用测试平台的实验研究中,该方法被证明是有用的,证明了令人满意的结果。但是,该测量装置还显示出与运输,净化和背景辐射屏蔽相关的不可行属性。在本文中,提出了一种新的测量装置的设计。它基于测试平台的经验,但是其尺寸和重量使其在运输和净化方面具有优势。此外,该设计固有地允许更有效的背景屏蔽。rn已经使用MCNP仿真代码对后者进行了详细研究。结果证实了在测试平台中观察到的高水平背景辐射。还得出结论,新设计中的屏蔽性能已足够。

著录项

  • 来源
    《Nuclear science and engineering》 |2010年第2期|232-239|共8页
  • 作者单位

    Vattenfall Power Consultant AB, P.O. Box 527, SE-162 16 Stockholm, Sweden;

    rnUppsala University, Department of Physics and Astronomy, P.O. Box 516, SE-751 20, Uppsala, Sweden;

    rnUppsala University, Department of Physics and Astronomy, P.O. Box 516, SE-751 20, Uppsala, Sweden;

    rnUppsala University, Department of Physics and Astronomy, P.O. Box 516, SE-751 20, Uppsala, Sweden;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号