首页> 外文期刊>Nuclear instruments and methods in physics research >Beam optimization of helium injector for coupled RFQ-SFRFQ linac
【24h】

Beam optimization of helium injector for coupled RFQ-SFRFQ linac

机译:耦合RFQ-SFRFQ直线加速器的氦气注入器的射束优化

获取原文
获取原文并翻译 | 示例
           

摘要

The coupled RFQ-SFRFQ (CRS) cavity designed in Peking University is a new type linac that coupled radio frequency quadrupole (RFQ) and separated function radio frequency quadrupole (SFRFQ) structure into a single cavity. An upgraded helium injector for the CRS cavity consisting of a 2.45 GHz permanent magnet electron cyclotron resonance (ECR) ion source and a 1.16 m low energy beam transport (LEBT) has been constructed and tested. The beam conditions of the injector were carefully optimized to satisfy the requirements of the CRS linac, the corresponding control system and a two-dimension scanner code CRSvl.O were developed for optimizing the beam transmission from LEBT section to the entrance of the CRS cavity. The beam transmission efficiency has reached to approximately 87.5% as well as the optimized operating parameters were obtained by means of the scanner code.
机译:北京大学设计的RFQ-SFRFQ耦合腔是一种新型直线加速器,它将射频四极(RFQ)和分离功能的射频四极(SFRFQ)结构耦合到一个腔中。已经构造并测试了用于CRS腔的升级版氦气注入器,该注入器由2.45 GHz永磁电子回旋共振(ECR)离子源和1.16 m低能束传输(LEBT)组成。精心优化了喷油器的射束条件,以满足CRS直线加速器的要求,并开发了相应的控制系统和二维扫描仪代码CRSv1.0以优化从LEBT截面到CRS腔入口的射束传输。光束传输效率已达到约87.5%,并且通过扫描仪代码获得了优化的操作参数。

著录项

  • 来源
  • 作者单位

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

    State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    CRS; Helium injector; Control system; Beam optimization;

    机译:CRS;氦气注射器控制系统;光束优化;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号