Characteristic impedance study of differential transmission lines based on Digital Sampling Oscilloscope is carried out, and more than 72 multi-gap resistive plate chambers (MRPC) with different structures have been developed and tested. The results show that the impedance is related to the overall electromagnetic field structure, which is determined by the number and width of gas gaps and glass, the number of stacks, and the width of signal strips. The equivalent dielectric constant of the dielectrics between the paired readout strips has been introduced and applied into Wheeler's equations. After that, the outcome of the equations corresponds with the test results. In addition, a new approximate formula for calculating the transmission-line impedance of multi-stack MRPC detectors is proposed. The values computed from the formula show a good agreement with the experimental data, thus demonstrating its validity.
机译:进行了基于数字采样示波器的差分传输线的特性阻抗研究,已开发并测试了72个不同结构的多间隙电阻板腔。结果表明,阻抗与整体电磁场结构有关,电磁场结构由气隙和玻璃的数量和宽度,堆叠的数量以及信号条的宽度决定。已将成对的读出条之间的电介质的等效介电常数引入并应用于惠勒方程。之后,方程式的结果与测试结果相对应。此外,提出了一种新的近似公式,用于计算多堆叠MRPC检测器的传输线阻抗。由公式计算出的值与实验数据显示出很好的一致性,从而证明了其有效性。