the helium circulator is a key component of 10 MW high temperature gas-cooled reactor (HTR-10), which has the helium coolant circulate inside the primary loop of the reactor. Before delivery. The performance experiment of the circulator was carried out in the factory at 0.426 Mpa, 250 deg. C nitrogen condition. In the paper, by using dimensional methodology, the experiment results are converted to those on 3.0 Mpa, 250 deg. C helium condition which is real working condition on the reactor. Then the circulator performances are analyzed. Finally, the operating performances on HTR-10 are predicted. The paper concludes that the circulator design was made correctly and the performances are satisfied with HTR-10 operating requirements.
机译:氦循环器是10 MW高温气冷堆(HTR-10)的关键组件,该反应器使氦冷却剂在反应器的主回路内循环。送达前。循环器的性能实验是在工厂以0.426 Mpa,250度进行的。 C氮条件。在本文中,通过使用尺寸方法,将实验结果转换为250摄氏度,3.0 Mpa的实验结果。氦气条件是反应堆上的实际工作条件。然后分析了循环器的性能。最后,对HTR-10的运行性能进行了预测。本文得出的结论是,循环器的设计正确,性能满足HTR-10的运行要求。