首页> 外文期刊>Nuclear Engineering and Design >Experimental studies on rewetting of hot vertical annular channel
【24h】

Experimental studies on rewetting of hot vertical annular channel

机译:热垂直环形通道再润湿的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Studies on the rewetting behaviour of hot vertical annular channels are of interest in the context of emergency core cooling in nuclear reactors following LOCA. Experimental studies were carried out to study the rewetting behaviour of a hot vertical annular channel, with hot inner tube, for bottom flooding and top flow rewetting conditions. The length of the inner tube of the test section was 3030 mm for bottom flooding rewetting experiments and 2630 mm for top flow rewetting experiments. The tube was made of stainless steel.
机译:在LOCA之后,在核反应堆中紧急堆芯冷却的背景下,对垂直垂直环形热通道的再湿润行为的研究值得关注。进行了实验研究,以研究在底部溢流和顶部水流再润湿条件下,带有热内管的垂直热环状环形通道的再润湿行为。对于底部溢流再湿润实验,测试段内管的长度为3030 mm,对于顶部流动再湿润实验为2630 mm。该管由不锈钢制成。