...
首页> 外文期刊>Mycopathologia >Comparative Analysis of the Vitek 2 Antifungal Susceptibility System and E-test with the CLSI M27-A3 Broth Microdilution Method for Susceptibility Testing of Indian Clinical Isolates of Cryptococcus neoformans
【24h】

Comparative Analysis of the Vitek 2 Antifungal Susceptibility System and E-test with the CLSI M27-A3 Broth Microdilution Method for Susceptibility Testing of Indian Clinical Isolates of Cryptococcus neoformans

机译:Vitek 2抗真菌药敏系统与E检验与CLSI M27-A3肉汤微量稀释法对印度新隐球菌临床分离株药敏试验的比较分析

获取原文
获取原文并翻译 | 示例
           

摘要

The emergence of antifungal resistance among Cryptococcus neoformans isolates is a matter of great concern. The Clinical and Laboratory Standards Institute (CLSI) broth microdilution reference method (BMD) for antifungal susceptibility testing of C. neoformans is tedious and time-consuming. Consequently, there is a greater need for a reproducible in vitro susceptibility testing method for use in clinical microbiology laboratories. By random amplified polymorphic DNA analysis, the 62 Indian clinical isolates were characterized as Cryptococcus neoformans var. grubii. We evaluated the susceptibilities of these isolates for amphotericin B (AMB) and fluconazole (FLC) by two commercial techniques, i.e., Vitek 2 and E-test against the CLSI M27-A3 BMD. The essential agreement (EA) between the Vitek 2 and E-test with the reference procedure for FLC was similar (82.2%). For AMB, EA of 92 and 76% was obtained with E-test and Vitek 2. Excellent categorical agreement (CA) (98.3% and 100% by Vitek 2 and E-test, respectively) was obtained for AMB. The CA for FLC was 81 and 77.4% by Vitek 2 and E-test. We conclude that both E-test and Vitek 2 system have acceptable levels of accuracy for susceptibility testing of both the drugs. Both of them could identify fluconazole-resistant strains. Vitek 2 could be used for testing susceptibility of voriconazole and 5-flucytosine also at the same time.
机译:新型隐球菌菌株中抗真菌耐药性的出现是一个令人高度关注的问题。临床和实验室标准协会(CLSI)肉汤微量稀释参考方法(BMD)用于新孢梭菌的抗真菌药敏性测试既繁琐又耗时。因此,更需要用于临床微生物学实验室的可再现的体外药敏试验方法。通过随机扩增多态性DNA分析,将62例印度临床分离株定性为新隐球菌。 grubii。我们通过两种商业技术,即Vitek 2和针对CLSI M27-A3 BMD的E-test,评估了这些分离株对两性霉素B(AMB)和氟康唑(FLC)的敏感性。 Vitek 2和E-test与FLC参考程序之间的基本协议(EA)相似(82.2%)。对于AMB,通过E-test和Vitek 2获得的EA分别为92%和76%。对于AMB,获得了出色的分类一致性(CA)(Vitek 2和E-test分别为98.3%和100%)。通过Vitek 2和E-test,FLC的CA分别为81和77.4%。我们得出的结论是,对于这两种药物的药敏试验,E-test和Vitek 2系统都具有可接受的准确性水平。他们俩都可以鉴定出耐氟康唑的菌株。 Vitek 2也可用于同时测试伏立康唑和5-氟胞嘧啶的敏感性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号