首页> 外文期刊>Microelectronics & Reliability >High temperature storage reliability of palladium coated copper wire in different EFO current settings
【24h】

High temperature storage reliability of palladium coated copper wire in different EFO current settings

机译:不同EFO电流设置下镀钯铜线的高温存储可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

In recent years, palladium-coated copper (PdCu) wire has been widely used in microelectronic packaging. The electronic flame off (EFO) current setting will affect the distribution of palladium (Pd) during the free air ball (FAB) formation of PdCu wire. This study investigates the influence of EFO current settings on Pd distribution in the FAB and the bonded ball. The distribution and concentration of Pd is observed by using an electron probe micro analyzer (EPMA). Mechanical tests are used to evaluate the bond strength of the first bond. A high temperature storage test (HTST) is performed on the packaged IC at 200 degrees C for 500 h and 1000 h.
机译:近年来,涂钯铜(PdCu)线已广泛用于微电子封装中。电子火焰(EFO)的电流设置将影响PdCu线的自由空气球(FAB)形成过程中钯(Pd)的分布。这项研究调查了EFO电流设置对FAB和键合球中Pd分布的影响。通过使用电子探针微分析仪(EPMA)观察Pd的分布和浓度。机械测试用于评估第一个粘结的粘结强度。在200℃下对封装的IC进行500h和1000h的高温存储测试(HTST)。