Wound roll electroactive polymer actuators fabricated with dielectric elastomer (DE) materials provide high bandwidth actuation for robots, minipumps, loudspeakers, valves, and prosthetic devices. In this paper, we develop a DE wound roll actuator fabrication process that produces high strain (12%), reliable (3480 cycles at maximum strain), and stiff (144 N/m) actuators. An axisymmetric finite element model with electrostatic and radial bulk modulus nonlinearity predicts actuator displacement and stress. The maximum compressive radial stress occurs at the center of the innermost active layer. This layer also has the thinnest material, indicating the most likely failure point. The nonlinear model predicts actuator displacement in response to applied voltage and load, matching experiments to within 1 mm.
机译:用介电弹性体(DE)材料制成的绕卷式电活性聚合物致动器为机器人,微型泵,扬声器,阀门和假肢设备提供了高带宽致动。在本文中,我们开发了DE卷绕辊致动器的制造工艺,该工艺可产生高应变(12%),可靠(在最大应变下为3480个循环)和刚性(144 N / m)致动器。具有静电和径向体积模量非线性的轴对称有限元模型可预测执行机构的位移和应力。最大压缩径向应力发生在最内层活性层的中心。该层还具有最薄的材料,表明最可能的故障点。非线性模型根据施加的电压和负载预测执行机构的位移,使实验匹配到1 mm以内。