The behaviour of prestressed concrete members with unbonded tendons is different from that of members with bonded tendons. While the behaviour of prestressed concrete beams with bonded tendons is characterised by that existing at individual sections, analysis of the entire member is necessary for beams with unbonded tendons. This paper examines various design methods for the determination of ultimate tendon stress at flexural failure of prestressed concrete beams with unbonded tendons. Two broad categories of deformation-based approaches have been identified, namely those based on the span—depth ratio together with loading type, and those based on the neutral axis depth. These methods are reviewed critically. A new design formula has been proposed in the light of the available experimental. data. It is applicable not only to the conventional high-strength steel prestressing tendons, but also to those made of other materials such as fibre-reinforced polymer.
机译:具有未粘结筋的预应力混凝土构件的性能不同于具有粘结筋的预应力混凝土构件的性能。带有预应力筋的预应力混凝土梁的特征是存在于各个截面中,但对于未预应力筋的梁,需要对整个构件进行分析。本文探讨了用于确定无粘结预应力混凝土梁弯曲破坏时的极限钢筋应力的各种设计方法。已经确定了基于变形的方法的两大类,即基于跨度-深度比以及载荷类型的方法,以及基于中性轴深度的方法。这些方法进行了严格审查。根据现有的实验,提出了一个新的设计公式。数据。它不仅适用于常规的高强度钢预应力筋,还适用于由其他材料制成的纤维,例如纤维增强聚合物。

著录项

  • 来源
    《Magazine of Concrete Research》 |2004年第1期|p.1-11|共11页
  • 作者

    F. T. K. Au; J. S. Du;

  • 作者单位

    Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, PR China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 水泥工业;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号