首页> 外文期刊>Journal of structural engineering >Cyclic Lateral Load Test for RC Column-Steel Beam Joints with Simplified Connection Details
【24h】

Cyclic Lateral Load Test for RC Column-Steel Beam Joints with Simplified Connection Details

机译:具有简化连接细节的钢筋混凝土柱-钢梁节点的循环侧向荷载试验

获取原文
获取原文并翻译 | 示例
           

摘要

Existing experimental results show that carefully designed RC column-to-steel beam (RCS) joints have high seismic resistance comparable to those of traditional steel or RC frames with seismic details. However, such high seismic performance requires complicated and expensive strengthening details, which causes difficulties in fabrication and construction. This study investigated simpler strengthening methods, targeting moderate seismic capacity. Four interior RCS joint specimens were tested under cyclic lateral loading. The major test parameters were the strengthening details of the beam-column joint such as face bearing plates, transverse beams, and headed studs. The test specimens with the proposed methods exhibited good deformation capacity exceeding 4.0% story drift ratio after yielding of the beams and beam-column connection. However, the peak load did not reach the nominal strength based on the beam plastic moment due to early joint damage. The failure modes and test strengths were compared with the predictions of ASCE design guidelines. On the basis of the results, design recommendations for the simplified connection details were proposed.
机译:现有的实验结果表明,精心设计的RC柱对钢梁(RCS)节点具有较高的抗震性能,可与具有抗震细节的传统钢框架或RC框架相媲美。然而,如此高的抗震性能需要复杂且昂贵的加强细节,这在制造和构造中造成困难。这项研究调查了针对中等地震能力的简单加固方法。在周期性的横向载荷下测试了四个内部RCS关节标本。主要测试参数是梁柱节点的加固细节,例如面板,横梁和带头螺栓。采用所提出方法的试样在屈服梁和梁柱连接后表现出良好的变形能力,超过了4.0%的层位移率。但是,由于早期的接头损坏,峰值载荷并未达到基于梁塑性矩的标称强度。将失效模式和测试强度与ASCE设计指南的预测进行了比较。根据结果​​,提出了简化连接细节的设计建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号