Determination of uranium in process stream solutions from uranium extraction plant employing energy dispersive X-ray fluorescence spectrometry

机译:能量分散X射线荧光光谱法测定铀提取厂工艺液中的铀。

获取原文
获取原文并翻译 | 示例
           

摘要

Energy dispersive X-Ray fluorescence (EDXRFS) method is developed and standardized for the determination of uranium on routine basis in various process stream solutions, covering a vide range of concentrations from 0.1 to 400 g L−1, from an Uranium Extraction Plant at Nuclear Fuel Complex. The method has been applied to aqueous stream samples. Except for dilution, no much sample preparation was involved in the analysis and accordingly the experimental parameters were optimized. The calibration curve in the range of 0.1–10 g L−1 of U was drawn manually using synthetic standard solutions prepared from U3O8 powder and Lα (13.61 keV) line of uranium was used for the measurements. The results from EDXRFS method are compared with other methods and are found to be in good agreement. The EDXRFS measurements carried over a range of 0.1–350 g L−1 of uranium have shown a RSD of ±1–5%. Also, the limitations of reported methods in literature and the advantages of present method are highlighted in the paper.
机译:能量色散X射线荧光(EDXRFS)方法已开发并标准化,可用于常规工艺中各种工艺流溶液中铀的测定,涵盖铀浓度范围从0.1到400 g L-1 核燃料综合体的提取厂。该方法已应用于水流样品。除了稀释外,分析中没有太多样品制备,因此优化了实验参数。使用由U3 O8 粉末和铀的Lα(13.61 keV)谱线制备的合成标准溶液,手动绘制了U–0.1–10 g L-1 范围内的校准曲线。用于测量。将EDXRFS方法的结果与其他方法进行比较,发现结果吻合良好。在0.1-350 g L-1 铀范围内进行的EDXRFS测量显示RSD为±1-5%。此外,本文还重点介绍了文献报道的方法的局限性和现有方法的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号