A commercial fuel cell backup power unit is tested in real life operating conditions at a base station of a Turkish telecom operator. The fuel cell system responds to 256 of 260 electric,power outages successfully, providing the required power to the base station. Reliability of the fuel cell backup power unit is found to be 98.5% at the system level. On the other hand, a qualitative reliability analysis at the component level is carried out. Implications of the power management algorithm on reliability is discussed. Moreover, integration of the backup power unit to the base station ecosystem is reviewed in the context of reliability. Impact of inverter design on the stability of the output power is outlined. Significant current harmonics are encountered when a generic inverter is used. However, ripples are attenuated significantly when a custom design inverter is used. Further, fault conditions are considered for real world case studies such as running out of hydrogen, a malfunction in the system, or an unprecedented operating scheme. Some design guidelines are suggested for hybridization of the backup power unit for an uninterrupted operation. (C) 2016 Elsevier B.V. All rights reserved.
机译:在土耳其电信运营商的基站的实际操作条件下对商用燃料电池备用电源进行了测试。燃料电池系统可成功响应260停电中的256停电,从而为基站提供所需的电力。在系统级别,燃料电池备用电源装置的可靠性为98.5%。另一方面,在组件级别进行了定性可靠性分析。讨论了电源管理算法对可靠性的影响。此外,在可靠性的背景下审查了备用电源单元与基站生态系统的集成。概述了逆变器设计对输出功率稳定性的影响。使用通用逆变器时会遇到大量电流谐波。但是,使用定制设计的逆变器时,纹波会大大衰减。此外,在实际案例研究中会考虑故障条件,例如氢气用尽,系统故障或空前的运行方案。对于不间断运行的备用电源单元的混合,建议了一些设计准则。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号