首页> 外文期刊>Journal of materials science >Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model
【24h】

Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model

机译:亲水性聚乙二醇涂层支架后的组织病理学反应和猪冠状动脉再狭窄模型中的疏水性十六烯藻涂层支架植入

获取原文
获取原文并翻译 | 示例
           

摘要

Device-related problems of drug-eluting stents, including stent thrombosis related to antiproliferative drugs and polymers, can cause adverse events such as inflammation and neointimal hyperplasia. Stent surface modification, wherein the drug and polymer are not required, may overcome these problems. We developed hydrophilic polyethylene glycol (PEG)-coating and hydrophobic octadecylthiol (ODT)-coating stents without a drug and polymer and evaluated their histopathologic response in a porcine coronary restenosis model. PEG-coating stents (n=12), bare-metal stents (BMS) (n=12), and ODT-coating stents (n=10) were implanted with oversizing in 34 porcine coronary arteries. Four weeks later, the histopathologic response, arterial injury, inflammation, and fibrin scores were analyzed. A p value0.05 was considered statistically significant. There were significant differences in the internal elastic lamina area, lumen area, neointimal area, percent area of stenosis, arterial injury score, inflammation score, and fibrin score among the groups. Compared to the BMS or ODT-coating stent group, the PEG-coating stent group had significantly increased internal elastic lamina and lumen area (all p0.001) and decreased neointimal area and percent area of stenosis (BMS: p=0.03 and p0.001, respectively; ODT-coating: p=0.013 and p0.001, respectively). Similarly, the PEG-coating group showed significantly lower inflammation and fibrin scores than the BMS or ODT-coating groups (BMS: p=0.013 and p=0.007, respectively; ODT-coating: p=0.014 and p=0.008, respectively). In conclusion, hydrophilic PEG-coating stent implantation was associated with lower inflammatory response, decreased fibrin deposition, and reduced neointimal hyperplasia than BMS or hydrophobic ODT-coating stent implantation in the porcine coronary restenosis model.
机译:与抗增殖药物和聚合物有关的药物洗脱支架的装置相关问题会导致炎症和新内膜增生等不良事件。支架表面改性,其中不需要药物和聚合物,可以克服这些问题。我们在没有药物和聚合物的情况下开发了亲水聚乙二醇(PEG) - 涂层和疏水性十八硫醇(ODT)涂料支架,并在猪冠状动脉再狭窄模型中评估它们的组织病理学反应。 PEG涂布支架(n = 12),裸金属支架(BMS)(N = 12)和ODT涂覆支架(n = 10),在34个猪冠状动脉中的过大。四周后,分析了组织病理学反应,动脉损伤,炎症和纤维蛋白评分。 P值& 0.05被认为是统计学意义。内部弹性薄层面积,腔面积,新内膜面积,狭窄,动脉损伤得分,炎症评分和纤维蛋白分数中存在显着差异。与BMS或ODT涂层支架组相比,PEG涂层支架基团具有显着增加的内部弹性薄层和腔面积(所有P <0.001)并降低内部区域和狭窄百分比(BMS:P = 0.03和P&LT; 0.001分别; Odt涂层:P = 0.013和P <0.001分别)。类似地,PEG涂布组显着降低炎症和纤维蛋白分别比BMS或ODT-涂布基团(BMS:P = 0.013和P = 0.007分别; ODT-涂层:P = 0.014和P = 0.008)。总之,亲水性PEG涂层支架植入与较低的炎症反应,纤维蛋白沉积降低,​​并降低了猪冠状动脉再狭窄模型中的基于BMS或疏水性ODT涂层支架植入的新内膜增生。

著录项

  • 来源
    《Journal of materials science》 |2020年第12期|122.1-122.8|共8页
  • 作者单位

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pusan Natl Univ Hosp Dept Internal Med Med Res Inst Div Cardiol Busan South Korea;

    Pohang Univ Sci & Technol POSTECH Dept Chem Engn Pohang South Korea;

    Pohang Univ Sci & Technol POSTECH Dept Chem Engn Pohang South Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类