首页> 外文期刊>Journal of Heat Transfer >Measurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate
【24h】

Measurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate

机译:使用真空保护热板测量总半球发射率

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, a new measurement method for the total hemispherical emissivity of surfaces is introduced. A vacuum guarded hot plate apparatus is developed and it is employed for the emissivity measurement. Al, Ag, Au, and Ni coatings and STS 304 plate are used as the specimen. Measured total hemispherical emissiv-, ities are 0.05-0.24 with 8.1% uncertainty at most. This proves the reliability of current method even for highly reflective surfaces.
机译:本文介绍了一种测量表面总半球发射率的新方法。开发了真空保护热板装置,并将其用于发射率测量。 Al,Ag,Au和Ni涂层和STS 304板用作样品。测得的总半球发射率为0.05-0.24,最大不确定度为8.1%。这证明了当前方法的可靠性,即使对于高反射表面也是如此。

著录项

  • 来源
    《Journal of Heat Transfer》 |2012年第11期|p.114501.1-114501.4|共4页
  • 作者单位

    Korea Advanced Institute of Science and Technology, 291 Daehak-ro(373-l Guseong-dong), Yuseong-gu, Daejeon 305-701, Republic of Korea;

    Korea Advanced Institute of Science and Technology, 291 Daehak-ro(373-l Guseong-dong), Yuseong-gu, Daejeon 305-701, Republic of Korea;

    Korea Advanced Institute of Science and Technology, 291 Daehak-ro(373-l Guseong-dong), Yuseong-gu, Daejeon 305-701, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    surface emissivity; vacuum guarded hot plate; metal coating;

    机译:表面发射率真空保护热板;金属涂层;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号