首页> 外文期刊>Journal of Harbin Institute of Technology >Passive control experiment of building with spacious first story by magnet-friction energy dissipation device
【24h】

Passive control experiment of building with spacious first story by magnet-friction energy dissipation device

机译:磁摩擦耗能装置对宽敞初层建筑的被动控制实验

获取原文
获取原文并翻译 | 示例
           

摘要

Based on the former performance capacity experiments of the magnet-friction energy dissipation devices, including the permanent magnet-friction energy dissipation device (PMF) and electromagnet-friction energy dissipation devices (EMF) , a 5-story steel frame model with spacious first story is designed and made according to a scale of 1/4. The magnet-friction energy dissipation devices can realize continuously varied controlling force, with rapid response and reverse recognition. Therefore, they overcome shortcomings usually found in energy dissipation devices whose force models are invariable. The two kinds of devices were fixed on the flexible first story of the structure model, and the shaking table tests have been carried out, respectively. In these tests, the performance of the devices and their effectiveness in structural control were confirmed. In this paper, the test results and analysis are discussed.
机译:基于以前的磁摩擦耗能装置的性能测试,包括永磁摩擦耗能装置(PMF)和电磁摩擦耗能装置(EMF),这是一个五层钢框架模型,具有宽敞的第一层楼是根据1/4的比例设计和制造的。磁摩擦耗能装置可实现连续变化的控制力,具有快速响应和反向识别的功能。因此,它们克服了在力模型不变的耗能设备中通常发现的缺点。将这两种设备固定在结构模型的第一层上,并分别进行了振动台测试。在这些测试中,确认了设备的性能及其在结构控制中的有效性。本文讨论了测试结果和分析。