Radon continuous monitoring in Altamira Cave (northern Spain) to assess user's annual effective dose

机译:连续监测阿尔塔米拉洞(西班牙北部)中的,以评估用户的年度有效剂量

获取原文
获取原文并翻译 | 示例
           

摘要

In this work, we present the values of radon concentration, measured by continuous monitoring during a complete annual cycle in the Polychromes Hall of Altamira Cave in order to undertake more precise calculations of annual effective dose for guides and visitors in tourist caves. The ~(222)Rn levels monitored inside the cave ranges from 186 Bq m~(-3) to 7120 Bq m~(-3), with an annual average of 3562 Bq m~(-3). In order to more accurately estimate effective dose we use three scenarios with different equilibrium factors (F=0.5, 0.7 and 1.0) together with different dose conversion factors proposed in the literature. Neither effective dose exceeds international recommendations. Moreover, with an automatic radon monitoring system the time remaining to reach the maximum annual dose recommended could be automatically updated.
机译:在这项工作中,我们介绍了concentration浓度,该值是通过在阿尔塔米拉洞(Altamira Cave)的Polychromes大厅中的一个完整的年度周期内进行连续监测而测得的,以便对游客洞穴中的向导和游客进行更精确的年度有效剂量计算。洞内监测到的〜(222)Rn水平范围从186 Bq m〜(-3)到7120 Bq m〜(-3),年平均为3562 Bq m〜(-3)。为了更准确地估计有效剂量,我们使用了三种具有不同平衡因子(F = 0.5、0.7和1.0)以及文献中提出的不同剂量转换因子的方案。两种有效剂量均未超过国际建议。此外,使用自动ra监测系统,可以自动更新达到建议的最大年剂量的剩余时间。