摘要

Atmospheric air samples were collected at 9 monitoring stations (A1 to A9) less than 2 km from the Paks Nuclear Power Plant (Paks NPP) and a background station (B24). The monthly integrated CO2 and total carbon (CO2+hydrocarbons (CnHm)) samples were collected to determine the excess C-14 activity at the vicinity of the NPP. The measurements providing the C-14/C-12 ratio of the monthly integrated samples were carried out on a MICADAS type AMS at HEKAL. Due to the relatively low (CO2)-C-14 emission of PWR type Paks reactors and (t)he local Suess effect, there was negligible excess C-14 activity at the investigated stations in the pure CO2 fraction during the investigated 2 years period (2015-2016). On the contrary, there was a detectable (although minor) excess at every station in the CnHm fraction. In case of CO2, the average Delta C-14 excess was 3.8 parts per thousand and the highest measured value was 91.2 parts per thousand at the A3 station in February 2015. In case of CnHm, the average excess was 31.1 parts per thousand and the highest measured value was 319.1 parts per thousand at the A4 station in February 2016. We applied PC-CREAM 08 modelling to investigate the observed excess C-14 activity at the environmental sampling stations, which depends on the distance from the NPP and the meteorological conditions, such as wind direction and wind speed. Meteorology data was collected at the operating area of the Paks NPP in a meteorology tower. The direct C-14 emission through the 120 m high stacks was measured in the NPP by liquid scintillation counting. These emission data and our model calculations explain the excess activity in the CnHm fraction at the A4 station, which is located only 915 m far from the NPP's stacks in the prevailing wind direction. The excess activity at A3 station (the farthest unit) probably came from the nearby NPP wastewater discharge point. The recently observed average excess and highest excess data is similar to the published data in former studies (Molnar et al., 2007; Veres et al., 1995) on Paks NPP, the highest (CO2)-C-14 and (CnHm)-C-14 excess are just a little higher than it was in the earlier studies, but in these former studies, the A3 station was not equipped with a radiocarbon monitoring unit and the level of radiocarbon emission was almost invisible from the wastewater discharge point.
机译:在距帕克斯核电站(Paks NPP)和背景站(B24)不到2公里的9个监测站(A1至A9)收集了大气样品。每月收集一次CO2和总碳(CO2 +烃(CnHm))样品,以确定NPP附近的过量C-14活性。提供每月积分样品的C-14 / C-12比值的测量是在HEKAL的MICADAS型AMS上进行的。由于压水堆式Paks反应堆的(CO2)-C-14排放量相对较低以及(局部)Suess效应,在研究的2年期间,纯CO2馏分中被研究站的C-14过量活性可忽略不计(2015-2016)。相反,在CnHm馏分中的每个站都有可检测到的(尽管很小)过量。对于二氧化碳,2015年2月A3站的Delta C-14平均过量为3.8千分之一,最高测量值为91.2千份。对于CnHm而言,平均过量为31.1千分之一。 2016年2月,A4站的最高测量值为千分之319.1。我们应用PC-CREAM 08模型调查了在环境采样站观测到的过量C-14活性,这取决于距NPP的距离和气象条件,例如风​​向和风速。气象数据是在气象塔的Paks NPP作业区收集的。通过液体闪烁计数在NPP中测量了通过120 m高烟囱的直接C-14排放。这些排放数据和我们的模型计算解释了A4站CnHm馏分中的过量活动,A4站沿主要风向距离NPP烟囱仅915 m。 A3站(最远的单元)的过量活动可能来自附近的NPP废水排放点。最近观测到的平均过量和最高过量数据与先前关于Paks NPP的研究(Molnar等,2007; Veres等,1995)中已发表的数据相似,最高(CO2)-C-14和(CnHm) -C-14过量仅略高于早期研究,但是在这些先前的研究中,A3站未配备放射性碳监测单元,并且从废水排放点几乎看不到放射性碳的排放水平。

著录项

  • 来源
    《Journal of Environmental Radioactivity》 |2020年第3期|106138.1-106138.11|共11页
  • 作者

  • 作者单位

    Hungarian Acad Sci Atomki Inst Nucl Res Isotope Climatol & Environm Res Ctr POB 51 H-4001 Debrecen Hungary|Univ Debrecen Doctoral Sch Phys Debrecen Hungary;

    Isotoptech Ltd Debrecen Hungary;

    Hungarian Acad Sci Atomki Inst Nucl Res Isotope Climatol & Environm Res Ctr POB 51 H-4001 Debrecen Hungary;

    Paks Nucl Power Plant Paks Hungary;

    Hungarian Acad Sci Atomki Inst Nucl Res Isotope Climatol & Environm Res Ctr POB 51 H-4001 Debrecen Hungary|Univ Arizona Dept Geosci Tucson AZ 85721 USA|Univ Arizona AMS Lab Tucson AZ 85721 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Nuclear power plant; Monitoring; Radiocarbon; Modelling; Hydrocarbon; CO2;

    机译:核电站;监控;放射性碳;造型;烃;二氧化碳;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号