Optimal capacity of energy storage for dynamic voltage restorer under electrical faults scenarios using SOS optimization algorithm: Case of south Algerian's electrical autonomous grid application

机译:使用SOS优化算法的电气故障场景下动态电压恢复器的最佳储能容量:以南阿尔及利亚的电力自主电网为例

获取原文
获取原文并翻译 | 示例
           

摘要

In the last decade, one of the Algeria's preoccupations is the power quality through its national electrical network such as voltage sags and swells, harmonic currents and voltages. The customers connected to the power distribution network suffer from these perturbations, to solve this problem custom power device is used which is called dynamic voltage restorer. This paper describes DVR principle and voltage restoration which will be connected to the 15 KV real autonomous networks in small village of south Algeria. Moreover, optimal energy capacity for the proposed devices based on Meta heuristic methods is presented. The dynamic voltage restorer (DVR) has newly established to protect the industrial facilities from voltage sags and other voltage disturbances. The compensation ability of DVR depends primarily on the maximum voltage injection aptitude and the amount of stored available within the restorer. A detailed procedure to design the optimal system is presented by using SOS algorithm based Advancement compensation (PAC) policy in order to improve the voltage property of the device. The planed approach employs Symbiotic Organism Search technique to search for optimal value of phase advancement angle equivalent to minimum power injection from the energy storage element such as a capacitor or battery and its results have been compared to the conventional DVR techniques. According to the achieved results and detailed analysis, The corresponding values of optimized energy are 13,278 W-h, 20.847 W-h and optimums phase advanced angles found 131.762°, 115.536° for 17% and 40% voltage sag happened through electrical distribution network. Finally, the proposed method has been compared with other methods available in the literature and is found effective and encouraging.
机译:在过去的十年中,阿尔及利亚的首要任务之一就是通过其国家电网获得电能质量,例如电压骤降和骤升,谐波电流和电压。连接到配电网络的客户受到这些干扰的困扰,为了解决此问题,使用了定制的电源设备,称为动态电压恢复器。本文介绍了DVR的原理和电压恢复功能,它们将连接到阿尔及利亚南部小村庄的15 KV实际自治网络。此外,提出了基于元启发式方法的拟议设备的最佳能量容量。动态电压恢复器(DVR)刚刚成立,旨在保护工业设施免受电压骤降和其他电压干扰的影响。 DVR的补偿能力主要取决于最大电压注入能力和恢复器中可用的存储量。通过使用基于SOS算法的提前补偿(PAC)策略,提出了设计最优系统的详细过程,以改善设备的电压特性。该计划方法采用共生有机体搜索技术来搜索相位提前角的最佳值,该相位提前角等于从诸如电容器或电池之类的储能元件中注入的最小功率,并且已将其结果与常规DVR技术进行了比较。根据获得的结果和详细分析,优化能量的相应值为13,278 W-h,20.847 W-h,并且通过配电网络发现了17%和40%的电压骤降的最佳相位超前角131.762°,115.536°。最后,将所提出的方法与文献中可用的其他方法进行了比较,并发现其有效和令人鼓舞。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号